table of contents

Owner's Information
Copy of Safety Label ............................................... 5
Decal Location . ........................................................ 5
Important Message . ................................................. 9
Before You Start . ...................................................... 9
Lighting / Shutdown Procedure ............................... 10
Warranty .................................................................. 58
Installer's information
Dimensions
P121E-11 See Thru . ................................................ 7
P131E-11 Pier ......................................................... 8
General Safety Information . ..................................... 16
Installation Checklist . ............................................... 16
Locating Your Gas Fireplace . ................................... 17
Clearances .............................................................. 18
Combustible Mantels ............................................... 18
Framing and Finishing ............................................. 19
Unit Assembly Prior to Installation . .......................... 20
Venting Introduction . ................................................ 20
Exterior Vent Terminal Locations ............................. 21
Terminations ............................................................ 25
Terminations ............................................................ 26
Terminations ............................................................ 28
Horizontal Terminations ........................................... 30
Vertical Terminations ............................................... 31
Installation Procedures ............................................ 32
................................................................................. 33
Conversion from NG to LP....................................... 35
On Demand Pilot (seven day safety timer)
Important information if using the appliance in CPI (continuous pilot mode) only
This appliance is a ProFlame 2 system fitted with the "On Demand" Pilot, a safety feature which will shut down the gas valve completely by extinguishing the
pilot light in the event of a continuous full seven days of inactivity.
This only applies if the CPI (continuous pilot) switch is in the "on" position in your remote control transmitter.
Each time the main burner shuts down, manually or through the call from the thermostat, the seven day timer starts again.
The seven day inactivity timer is controlled within the circuit board. Therefore, if in CPI mode and when the pilot light is extinguished after seven straight days
of inactivity, the CPI setting on the remote control transmitter will remain in the "CPI" (continuous pilot) position. Therefore, all that is required to relight the pilot
would be to press the on/off button on the remote control transmitter from "on" to "off" and back to "on". Once the pilot has re-established operation will resume
as normal. There is no requirement to do anything with the IPI/CPI mode on the remote control transmitter.
If the unit never goes as long as seven full days without a call for heat, the pilot will remain lit until it is manually shut-off.
If the unit is being operated in IPI (intermittent pilot) mode, neither the above instructions nor the seven day timer will apply.
See the instructions in this manual and on the Lighting Instructions plate on the appliance to light or re-light the pilot.
|
4
Regency
P121E-11/P131E-11 Zero Clearance Direct Vent Gas Fireplace
®
System Data ............................................................ 36
High Elevation . ......................................................... 36
Gas Line Installation ................................................ 36
Flame Pattern .......................................................... 36
Gas Pipe Pressure Testing ...................................... 36
885 S.I.T. Valve Description ..................................... 36
Installation ............................................................... 37
Log Set Installation .................................................. 38
Safety Screen Removal ........................................... 40
Glass Door Removal................................................ 41
Finishing Trim........................................................... 41
Wall Thermostat (Optional) . .................................... 42
Terminal Block Location . .......................................... 42
Wiring Diagram without Thermostat ........................ 43
Optional Wall Thermostat ....................................... 44
First Fire .................................................................. 45
Operating Instructions ............................................. 45
Battery Backup ........................................................ 46
Maintenance Instructions......................................... 47
Flame Pattern .......................................................... 47
Aeration Adjustment ................................................ 48
Maintenance Instructions......................................... 49
Log Replacement .................................................... 49
Glass Gasket .......................................................... 49
Door Glass . .............................................................. 49
Removal of Valve Assembly..................................... 50
Installing Valve . ........................................................ 53
Fan Replacement .................................................... 53
Parts
P121E-11 (See Thru) Main Assembly ..................... 54
P131E-11 (Pier) Main Assembly ............................. 55
Warranty .................................................................. 58