Zero clearance direct vent gas fireplace (80 pages)
Summary of Contents for Regency P48-LP2
Page 1
Gas Connection Inset Gas Connection Width Important: Framing height requires consideration of the hearth depth. Dimension H = H + the thickness of installed hearth. June 2007 Regency Product Specifi cations Book P48-LP2 Propane 12” W.C. (3.00 kPa) 11” W.C. (2.74 kPa) 3.3”...
Combustible mantel leg clearances as per diagram below: Clearances are from the fi nished edge of the unit Maximum 1-½” projection at 3” minimum clearance. June 2007 Regency Product Specifi cations Book Clearance Dimension 2-1/2” (64mm) 1-1/2” (38mm) 1-1/2” (38mm) 1-1/4”...
S.S. screws #8 x 1-1/2” drill point, (4) 10) vinyl siding standoff Notes: Liner sections should be continuous without any joints or seams. Only Flex pipe purchased from Regency may be used for Flex installations. Horizontal sections must be supported every 3 feet. Vinyl Siding...
Wall Thimble Horizontal Termination Cap # 946-623/P Vinyl Siding Standoff Wall Thimble Termination Caps Alternate Snorkel Termination Cap Part #1282 (14”) Part #1281 (36”) Minimum 12” (305mm) Max. 10’ (3m)(centerline to centerline) June 2007 Regency Product Specifi cations Book 12 12...
Page 5
90° elbows is required. 5’ Max. 5’ Min. 6’ Max. 6’ Min. June 2007 Regency Product Specifi cations Book Vertical Venting with Three (3) 90° Elbows - Initial vertical section. Two 45° elbows = One 90° elbow Option H + H1...