Regency Panorama P121E-NG11 Owners & Installation Manual page 51

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

121E-11 /131E-11
7. Remove burner by removing four (4) Phillips head screws located in
each corner of the burner.
8. Once the burner has been loosened from the mounting brackets, slide
the burner off the orifice by sliding the burner right then up and out.
9. To remove the valve assembly from the unit, remove 16 Phillips head
screws securing the valve tray to the unit.
920-081
10. Remove the green, orange and yellow wire from the valve.
11. Remove the two Philips heads screws securing the IFC heat shield
once the screws have been loosened up remove the shied. Once the
shield has been removed disconnect the stepper motor from the IFC
at terminal X6 and the spark electrode wire from X2 as well as the
flame sensor wire from terminal X 3.
2
Regency
P121E-11/P131E-11 Zero Clearance Direct Vent Gas Fireplace
®
maintenance
03.07.19
|
51