Venting Arrangement - Horizontal Terminations - Regency Panorama P121E-NG11 Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

installation

Venting Arrangement - Horizontal Terminations

Regency
Direct Vent System (Flex) Horizontal Terminations Only
®
These venting systems, in combination with the P121E-11/P131E-11 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater
system by Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior
Vent Termination Locations" section.
Regency
Direct Vent (Flex) System Termination Kit (Part# 946-513) includes all the parts needed to install the P121E-11/P131E-11 with a
®
maximum run of 2 feet. If installing the P121E-11/P131E-11 with a continuous vent length of more than 2 ft. (.6m) to a maximum of 10 ft. (3.0m)
use Kit # 946-515 (4 ft.) or 946-516 (10 ft.)
1) 6-7/8" dia. flexible liner (2 ft. length)
2) 4" dia. flexible liner (2 ft. length)
3) spring spacers (3)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" drill point, stainless steel (4)
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency
3)
Regency
Direct Vent System (Flex) is only approved for horizontal terminations.
®
|
24
Regency
P121E-11/P131E-11 Zero Clearance Direct Vent Gas Fireplace
®
4" dia. flue pipe
6-7/8"
(17 mm)
5
dia. Flue pipe
may be used for Flex installations.
®
Wall Thimble
(required in
Canada only)
spring spacer
TM
AstroCap
Termination Cap
(Part# 946-523/P)