Option 1:
WALL SWITCH
1) Run supplied 15' of wire through the right
or left side gas inlet opening. Be careful not
to damage wire.
Note: We recommend a maximum of 15'
of wire but if you wish to go with a
longer run, use the Thermostat Wire
Table.
2) Connect wire to supplied wall switch and
install into the receptacle box.
CAUTION
Do not connect millivolt
wall switch wires for gas
appliance to a 240V power supply.
®
Regency
P36-4 Gas Log Fireplace
Option 2:
REMOTE CONTROL
Use the Regency
®
Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1) Choose a convenient location on the wall
to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace to
that location. Use Thermostat Wire Table.
2) Connect the two wires to the gas valve. See
diagram below.
CAUTION
Do not connect millivolt
remote control wires for
gas appliance to a
240V power supply.
3) Install a 9V alkaline battery in both the
receiver and the transmitter. Install the
receiver and its cover in the wall. Switch the
hand held remote transmitter to "remote"
mode. The remote control is now ready for
operation.
INSTALLATION
Option 3:
WALL THERMOSTAT
A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram.
Use chart below to determine the maximum
wire length.
Note: Preferable if the thermostat is
installed on an interior wall.
®
Regency
offers a programmable thermostat
but any CSA, UCL or UL approved millivolt
thermostat, 250-750 millivolt rated non-
anticipator type thermostat may be used.
CAUTION
Do not connect millivolt
wall thermostat wires for
gas appliance to a
240V power supply.

Thermostat Wire Table

Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
15.24 m
9.75 m
6.10 m
3.66 m
2.71 m