Locating Your
Gas Fireplace
1) When selecting a location for your fireplace,
ensure that the clearances are met as outlined
in the "Clearances" section.
2) Provide adequate clearances for servicing.
3) The appliance must be installed on a flat, solid,
continuous surface (e.g. wood, metal, concrete).
This may be the floor, or raised up on a platform
to enhance its visual impact. If the appliance is
going to be installed on carpeting, combustible
linoleum tile or other combustible material other
than wood flooring, the appliance must be
installed on a metal or wood panel extending
the full width and depth of the appliance.
4) The Direct Vent Gas Fireplace can be installed
as follows:
Model #
Position
A)
P121E-11:
B)
P131E-11:
5) This appliance is Listed for bedroom installations
when used with a Listed Millivolt Thermostat.
Some areas may have further requirements,
check local codes before installation.
6) The P121E-11/P131E-11 Direct Vent Gas
Fireplace is approved for alcove installations,
which meet the clearances listed on this page.
7) We recommend that you plan your installation on
paper using exact measurements for clearances
and floor protection before actually installing this
appliance. Have a qualified inspector, dealer, or
installer review your plans before installation.
Note: For Exterior Vent Termination
Locations see section "Exterior Vent
Termination Locations."
A) P121E-11 See Thru
B) P131E-11 Pier
See Thru
Pier
Regency
P121E-11/P131E-11 Zero Clearance Direct Vent Gas Fireplace
®

installation

|