REQUIRED FIRESTOP, RADIATION SHIELD, OR ATTIC INSULATION SHIELD
Model
1st Floor
AMERI-TEC 3103 Firestop Assembly (FSA)
GSW JFC
Firestop/Radiation Shield (FRS) Firestop Attic Insulation Shield (JSC-FAIS)
GSW FC
Firestop Radiation Shield (FRS) Firestop Attic Insulation Shield(JSC-FAIS)
ICC Excel 103HT Radiation Shield (RS)
ICC Excel 2100
Radiation Shield (RS)
O.M. PRO-JET
Firestop Radiation Shield
Security ASHT
Firestop Radiation Shield (RS)
Security 2100
Radiation Shield (XRSA)
Selkirk SS
Radiation Dustshield
Selkirk SSII
Firestop Wallspacer
Simpson
Firestop Radiation Shield
DURA-PLUS
MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET
(Measured from the top of the solid fuel appliance)
ELEVATION (FT)
0
ABOVE SEA LEVEL
0-1000
12.00
1000-2000
12.48
2000-3000
12.96
3000-4000
13.44
4000-5000
13.92
5000-6000
14.40
6000-7000
14.88
7000-8000
15.36
8000-9000
15.84
9000-10000
16.32
ular operation because the unit uses out-
side air for combustion, not room air.
2) Multiple Terminations.
stall more than one chimney in the same
chase or within the same general area, we
suggest that their terminations be separat-
ed by at least 16 in. (410 mm) horizontally
and 18 in.
(460 mm) vertically.
separation is to prevent smoke migrating
from one chimney to another.
12
TABLE 1
FSA with Attic Insulation Shield (AIS)
Radiation shield (RS) with Storm Collar (SC)
Radiation shield (RS) with Storm Collar (SC)
Joist Shield with Attic Insulation Shield
Radiation Shield with Attic Insulation Shield
(RS,RSA)
Radiation Shield (XRSA)
Attic Insulation Shield
Firestop Wallspacer with Attic Insulation Shield
Firestop Radiation Shield with Attic Insulation
Shield
TABLE 2
# OF ELBOWS
o
o
o
2 x 15
4 x 15
2 x 30
13.00
14.00
15.0
13.52
14.56
15.6
14.04
15.12
16.2
14.56
15.68
16.8
15.08
16.24
17.4
15.60
16.80
18.0
16.12
17.36
18.6
16.64
17.92
19.2
17.16
18.48
19.8
17.68
19.04
20.4
3) Chimney Maintenance.
that you inspect your chimney regularly and
keep it clean. If you note more than 1/8 in.
When you in-
creosote build up in your chimney have it
cleaned as per instructions of the chimney
manufacturer.
4) Chimney Fires. If you do have a chimney
This
fire, refer to the following:
a. Close the fireplace doors and air damp-
er.
2nd Floor into Attic
o
o
o
4 x 30
2 x 45
4 x 45
18.00
16.00
20.0
18.72
16.64
20.0
19.44
17.28
21.6
20.16
17.92
22.4
20.88
18.56
23.2
21.60
19.20
24.0
22.32
19.84
24.8
23.04
20.48
25.6
23.76
21.12
26.4
24.48
21.76
27.2
It is important
b. Clear family members out of the area.
c. Call the fire department.
d. Use a dry chemical fire extinguisher,
baking soda or sand to control the fire.
Do not use water, it will create a
steam explosion.
e . Check for hot embers around the unit
and outside your home; extinguish.
f. Do not use your fireplace again until it
has been inspected by a qualified
person.

Offset Chimney Installation

Chimney elbows may be used in the installation
of the system. A maximum of four 45 degree
elbows are allowed. This may be achieved by
combining 30 degree and 15 degree elbows
together if necessary and allowed by the
chimney manufacturer. Offset angles of 45,
30 and 15 degrees are allowed with a maxi-
mum of 2 offsets.
1) Install the fireplace and chimney as de-
scribed above.
When you require an
elbow, proceed as follows:
2) Install the insulated elbow. Turn the elbow
to the required direction and fasten it with
screws or locking bands depending on
flue design as specified by the manufac-
turer.
3) Turn the chimney lengths clockwise to lock
them together, then secure them with
screws at each joint or locking bands; see
the manufacturers requirements.
4) Use another elbow to return the chimney
to vertical.
5) Install an offset
support in the joist
at the ceiling. Re-
support
each offset; el-
bows are not de-
signed to carry the
weight of the flue
system.
Regency Z2510 WarmHearth