Regency Panorama P121E-NG11 Owners & Installation Manual page 27

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

Horizontal Venting with Two (2) 90
Option
V
A)
1' (305mm) Minimum
B)
2' (610mm) Minimum
C)
3' (914mm) Minimum
D)
4' (1.22m) Minimum
E)
5' (1.52m) Minimum
F)
6' (1.83m) Minimum
With the above options, maximum total pipe length if 37 feet with
minimum of 6 feet total vertical and maximum 15 feet total horizontal.
Please note minimum 1 foot between 90
Diagram 3
Horizontal Venting with Two (2) 90
Option
V
A)
1' (305mm) Min. 1' (305mm) Max. 3' (914mm) Max.
B)
2' (610mm) Min. 3' (0.91m) Max. 6' (1.83m) Max.
C)
3' (914mm) Min. 5' (1.52m) Max. 9' (2.74m) Max.
D)
5' (1.52m) Min.
With the above options, maximum total pipe length if 37 feet with
minimum of 5 feet total vertical and maximum 12 feet total horizontal.
Please note minimum 1 foot between 90
Diagram 4
Elbows
o
H + H1
2' (610mm) Maximum
5' (1.53m) Maximum
8' (2.44m) Maximum
11' (3.35m) Maximum
14' (4.27m) Maximum
15' (4.57m) Maximum
o
elbows is required.
Elbows
o
H
H + H1
8' (2.44m) Max. 12' (3.66m) Max.
elbows is required.
o
Horizontal Venting with Three (3) 90
Option
A)
2' (610mm) Min. 1' (305mm) Max. 3' (914mm) Max.
B)
3' (914mm) Min. 3' (914mm) Max. 6' (1.83m) Max.
C)
4' (1.22mm) Min. 5' (1.52m) Max. 9' (2.74m) Max.
D)
5' (1.52m) Min.
With the above options, maximum total pipe length if 37 feet with
minimum of 5 feet total vertical and maximum 12 feet total horizontal.
Please note minimum 1 foot between 90
Diagram 5
Horizontal Venting with Three (3) 90
Option
A)
2' (610mm) Minimum
B)
3' (914mm) Minimum
C)
4' (1.22m) Minimum
D)
5' (1.52m) Minimum
With the above options, maximum total pipe length if 37 feet with
minimum of 5 feet total vertical and maximum 12 feet total horizontal.
Please note minimum 1 foot between 90
Diagram 6
Regency
P121E-11/P131E-11 Zero Clearance Direct Vent Gas Fireplace
®
Elbows
o
V
H
7' (2.13m) Max. 12' (3.66m) Max.
elbows is required.
o
Elbows
o
V + V1
3' (914mm) Maximum
6' (1.83m) Maximum
9' (2.7m) Maximum
12' (3.66m) Maximum
elbows is required.
o
installation
H + H1 + H2
H + H1
|
27

Hide quick links:

Advertisement

Table of Contents
loading