Wall Mount On / Off Switch and Battery Holder Installation
Required for all installations
IMPORTANT INSTALLATION NOTE:
The Battery Holder must be placed inside the supplied (Low Voltage) junction type wall box and installed into
the wall only.
DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE
SWITCH MUST BE ACCESSIBLE
Battery Holder Installation
1. Install the low voltage junction box to the framing, at desired location within 15 ft. from fireplace.
2. F eed the 6 pin connector through the opening at back of junction box.
3. Connect the 6 pin connector to the back of the Battery Holder.
4. Install the Battery Holder in the Low Voltage Junction box.
5. I nstall batteries only if 120 volt power will not be used. Batteries are only used if power is lost within the
home and serve as a secondary power source. Insert the 4 AA type batteries in the battery compartment
with the correct polarity.
6. Place the slider into the cover plate.
7. Put the Battery Holder switch in the "OFF" position, to allow correct lineup for slider switch.
8. Make sure the Battery Holder and cover plate words "ON" and "UP" are on the same side.
9. Align the slider with the switch on the Battery Holder and couple the switch into the slider.
10. Align the screw holes.
11. Using the two (2) screws provided secure the cover plate to the Battery Holder.
12. For coding instructions, see full details in this manual.
Proflame Battery Holder
Slider Switch
Wall Plate
Regency
P121E-11/P131E-11 Zero Clearance Direct Vent Gas Fireplace
®
installation
Low Voltage Junction Box
J-Box
Battery Holder
Diagram 1
|