Configure Volume Flow Type For Liquid Applications; Configure Volume Flow Measurement Unit For Liquid Applications - Emerson Micro Motion 2700 Configuration And Use Manual

Transmitters with intrinsically safe outputs
Hide thumbs Also See for Micro Motion 2700:
Table of Contents

Advertisement

Restriction
You cannot implement both liquid volume flow and gas standard volume flow at the same time.
Choose one or the other.
Note
If you need to switch from gas standard volume to liquid volume, polling for base density will
automatically be disabled.
4.2.1

Configure Volume Flow Type for liquid applications

Display
ProLink III
Field Communicator Configure > Manual Setup > Measurements > GSV > Volume Flow Type > Liquid
Overview
Volume Flow Type controls whether liquid or gas standard volume flow measurement will
be used.
Restriction
Gas standard volume measurement is incompatible with some applications. Set Volume Flow Type
to Liquid if you are using any of the following applications:
Procedure
Set Volume Flow Type to Liquid.
4.2.2
Configure Volume Flow Measurement Unit for liquid
applications
Display
ProLink III
Field Communicator Configure > Manual Setup > Measurements > Flow > Volume Flow Unit
Configuration and Use Manual
Not available
Device Tools > Configuration > Process Measurement > Flow
Petroleum measurement
Concentration measurement
Fuel consumption
Production Volume Reconciliation (PVR)
OFF-LINE MAINT > OFF-LINE CONFG > UNITS > VOL
Device Tools > Configuration > Process Measurement > Flow
Configure process measurement