Switchport Native Vlan - SMC Networks SMC8126L2 Management Manual

Tigerswitch 10/100/1000 26/50-port gigabit managed switch
Hide thumbs Also See for SMC8126L2:
Table of Contents

Advertisement

4
Command Line Interface
Command Mode
Interface Configuration (Ethernet, Port Channel)
Command Usage
• Ingress filtering only affects tagged frames.
• With ingress filtering enabled, a port will discard received frames tagged for
VLANs for it which it is not a member.
• Ingress filtering does not affect VLAN independent BPDU frames, such as
GVRP or STA. However, they do affect VLAN dependent BPDU frames, such
as GMRP.
Example
The following example shows how to select port 1 and then enable ingress filtering:
Console(config)#interface ethernet 1/1
Console(config-if)#switchport ingress-filtering
Console(config-if)#

switchport native vlan

This command configures the PVID (i.e., default VLAN ID) for a port. Use the no
form to restore the default.
Syntax
switchport native vlan vlan-id
no switchport native vlan
vlan-id - Default VLAN ID for a port. (Range: 1-4094, no leading zeroes)
Default Setting
VLAN 1
Command Mode
Interface Configuration (Ethernet, Port Channel)
Command Usage
• Setting the native VLAN for a port can only be performed when the port is a
member of the VLAN and the VLAN is untagged. The no switchport native
vlan command will set the native VLAN of the port to untagged VLAN 1.
• If acceptable frame types is set to all or switchport mode is set to hybrid, the
PVID will be inserted into all untagged frames entering the ingress port.
Example
The following example shows how to set the PVID for port 1 to VLAN 3:
Console(config)#interface ethernet 1/1
Console(config-if)#switchport native vlan 3
Console(config-if)#