Page 2
TigerSwitch 10/100/1000 Installation Guide From SMC's Tiger line of feature-rich workgroup LAN solutions 20 Mason September 2009 Pub. # 150200000032A Irvine, CA 92618 E092009-MW-R01 Phone: (949) 679-8000...
Page 3
No license is granted by implication or otherwise under any patent or patent rights of SMC. SMC reserves the right to change specifications at any time without notice.
Page 4
Warranty and Product Registration To register SMC products and to review the detailed warranty statement, please refer to the Support Section of the SMC Website at http://www.smc.com.
Page 5
Compliances and Safety Warnings FCC - Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Page 6
CE Mark Declaration of Conformance for EMI and Safety (EEC) This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC.
Safety Compliance Warning: Fiber Optic Port Safety When using a fiber optic port, never look at the transmit laser while it is powered on. Also, never look directly at the fiber TX port and fiber cable CLASS I ends when they are powered on. LASER DEVICE Avertissment: Ports pour fibres optiques - sécurité...
Page 8
France and Peru only This unit cannot be powered from IT † supplies. If your supplies are of IT type, this unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point labelled Neutral, connected directly to earth (ground). Important! Before making connections, make sure you have the correct cord set.
Page 9
• L’appareil fonctionne à une tension extrêmement basse de sécurité qui est conforme à la norme IEC 60950. Ces conditions ne sont maintenues que si l’équipement auquel il est raccordé fonctionne dans les mêmes conditions. France et Pérou uniquement: Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos alimentations sont du type impédance à...
Page 10
• Este equipo opera bajo las condiciones SELV (Safety Extra Low Voltage o Voltaje extra bajo de seguridad) de acuerdo con la norma IEC 60950. Las condiciones sólo se mantienen si la equipo al cual está conectado también opera bajo condiciones SELV.
Bitte unbedingt vor dem Einbauen des Switches die folgenden Sicherheitsanweisungen durchlesen: WARNUNG: Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal erfolgen. • Das Gerät sollte nicht an eine ungeerdete Wechselstromsteckdose angeschlossen werden. • Das Gerät muß an eine geerdete Steckdose angeschlossen werden, welche die internationalen Sicherheitsnormen erfüllt.
Advertencias y mensajes de precaución Advertencia: Este producto no contiene ninguna pieza reparable por el usuario. Advertencia: La instalación y remoción del equipo sólo debe ser llevada a cabo por personal calificado. Advertencia: Cuando enchufe este aparato a un tomacorriente, conecte el cable de tierra del enchufe tripolar a una línea válida de tierra física para prevenir riesgos de tipo eléctrico.
Purpose This guide details the hardware features of the switches, including their physical and performance-related characteristics, and how to install each switch. Audience This guide is for system administrators with a working knowledge of network management. You should be familiar with switching and networking concepts. Esta guía es para los administradores de sistemas que cuenten con conocimientos básicos de gestión de redes.
Contents Chapter 1: Introduction Overview Switch Architecture Power-over-Ethernet Capability Network Management Options Description of Hardware 10/100/1000BASE-T Ports SFP Slots Port and System Status LEDs Mode PoE/Link Button Optional Redundant Power Unit Power Supply Socket Features and Benefits Connectivity Expandability Performance Management Chapter 2: Network Planning Introduction to Switching...
Page 16
Contents Connecting to the Console Port Wiring Map for Serial Cable Chapter 4: Making Network Connections Connecting Network Devices Twisted-Pair Devices Cabling Guidelines Connecting to PCs, Servers, Hubs and Switches Network Wiring Connections Fiber Optic SFP Devices Connectivity Rules 1000BASE-T Cable Requirements 1000 Mbps Gigabit Ethernet Collision Domain 100 Mbps Fast Ethernet Collision Domain 10 Mbps Ethernet Collision Domain...
Page 17
Contents Appendix D: Ordering Information Appendix E: Spanish Instructions Selección de un sitio Montaje en bastidor Glossary Index xiii...
Page 18
Tables Table 1-1 Port Status LEDs Table 1-2 System Status LEDs Table 3-1 Serial Cable Wiring Table 4-1 Maximum 1000BASE-T Gigabit Ethernet Cable Length Table 4-2 Maximum 1000BASE-SX Gigabit Ethernet Cable Length Table 4-3 Maximum 1000BASE-LX Gigabit Ethernet Cable Length Table 4-4 Maximum 1000BASE-ZX Gigabit Ethernet Cable Length Table 4-5...
Page 19
Figures Figure 1-1 Front Panel Figure 1-2 Rear Panel Figure 1-3 Port LEDs Figure 1-4 System LEDs Figure 1-5 Mode Selection Figure 1-6 Power Supply Socket Figure 2-1 Collapsed Backbone Figure 2-2 Network Aggregation Plan Figure 2-3 Remote Connections with Fiber Cable Figure 2-4 Making VLAN Connections Figure 3-1...
Chapter 1: Introduction Overview The TigerSwitch 10/100/1000, SMC8126PL2-F, is an intelligent Layer 2 switch with 26 10/100/1000BASE-T ports, four of which are combination ports that are shared with four SFP transceiver slots (see Figure 1-1, Ports 21-24). The switch’s 24 10/100/1000 Mbps ports support the IEEE 802.3af Power-over-Ethernet (PoE) standard that enables DC power to be supplied to attached devices over wire pairs in the connecting Ethernet cable.
Introduction Switch Architecture The SMC8126PL2-F employs a wire-speed, non-blocking switching fabric. This permits simultaneous wire-speed transport of multiple packets at low latency on all ports. It also features full-duplex capability on all ports, which effectively doubles the bandwidth of each connection. This switch uses store-and-forward switching to ensure maximum data integrity.
Description of Hardware Description of Hardware 10/100/1000BASE-T Ports The SMC8126PL2-F contains 26 RJ-45 ports that operate at 10 Mbps or 100 Mbps, half or full duplex, or at 1000 Mbps, full duplex. Because all ports on this switch support automatic MDI/MDI-X operation, you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs.
Introduction Table 1-1 Port Status LEDs Label Color Description Port 1-24 On/Flashing Amber Port has a valid link at 10 or 100 Mbps. Flashing indicates activity. (Link/Activity/ On/Flashing Green Port has a valid link at 1000 Mbps. Flashing indicates activity. Speed Mode) There is no valid link on the port.
Description of Hardware Mode PoE/Link Button The Mode PoE/Link button is located on the front panel. Mode Select Button Figure 1-5 Mode Selection The Mode PoE/Link button is used to toggle between the two port status LED display modes (see "Port and System Status LEDs" on page 1-3). Pressing this button changes from one display mode to the other.
Introduction Features and Benefits Connectivity • 26 10/100/1000 Mbps ports for easy Gigabit Ethernet integration and for protection of your investment in legacy LAN equipment. • Auto-negotiation enables each RJ-45 port to automatically select the optimum communication mode (half or full duplex) if this feature is supported by the attached device;...
Chapter 2: Network Planning Introduction to Switching A network switch allows simultaneous transmission of multiple packets via non-crossbar switching. This means that it can partition a network more efficiently than bridges or routers. These switches have, therefore, been recognized as one of the most important building blocks for today’s networking technology.
Network Planning Application Examples The SMC8126PL2-F is not only designed to segment your network, but also to provide a wide range of options in setting up network connections. Some typical applications are described below. Collapsed Backbone The SMC8126PL2-F is an excellent choice for mixed Ethernet, Fast Ethernet, and Gigabit Ethernet installations where significant growth is expected in the near future.
Application Examples Network Aggregation Plan With 26 parallel bridging ports (i.e., 26 distinct collision domains), a switch can collapse a complex network down into a single efficient bridged node, increasing overall bandwidth and throughput. In the figure below, the 10/100/1000BASE-T ports are providing 1000 Mbps connectivity through Layer 2 switches.
Network Planning Remote Connections with Fiber Cable Fiber optic technology allows for longer cabling than any other media type. A 1000BASE-SX (MMF) link can connect to a site up to 550 meters away, a 1000BASE-LX (SMF) link up to 5 km, and a 1000BASE-ZX link up to 100 km. This allows a switch to serve as a collapsed backbone, providing direct connectivity for a widespread LAN.
Application Examples Making VLAN Connections This switch support VLANs which can be used to organize any group of network nodes into separate broadcast domains. VLANs confine broadcast traffic to the originating group, and can eliminate broadcast storms in large networks. This provides a more secure and cleaner network environment.
Network Planning Application Notes Full-duplex operation only applies to point-to-point access (such as when a switch is attached to a workstation, server or another switch). When the switch is connected to a hub, both devices must operate in half-duplex mode. For network applications that require routing between dissimilar network types, you can attach these switches directly to a multi-protocol router.
Chapter 3: Installing the Switch Selecting a Site The SMC8126PL2-F can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to follow the guidelines below when choosing a location. • The site should: - be at the center of all the devices you want to link and near a power outlet. - be able to maintain its temperature within 0 to 45 °C (32 to 113 °F) and its humidity within 10% to 90%, non-condensing - provide adequate space (approximately five centimeters or two inches) on all...
Installing the Switch RJ-45 Connector Figure 3-1 RJ-45 Connections Equipment Checklist After unpacking the switch, check the contents to be sure you have received all the components. Then, before beginning the installation, be sure you have all other necessary installation equipment. Package Contents •...
Mounting Mounting This switch can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instructions for each type of site follow. Rack Mounting Before rack mounting the switch, pay particular attention to the following factors: •...
Installing the Switch Mount the device in the rack, using four rack-mounting screws (not provided). Figure 3-3 Installing the Switch in a Rack If installing a single switch only, turn to "Connecting to a Power Source" at the end of this chapter. If installing multiple switches, mount them in the rack, one below the other, in any order.
Installing an Optional SFP Transceiver If installing a single switch only, go to "Connecting to a Power Source" at the end of this chapter. If installing multiple switches, attach four adhesive feet to each one. Place each device squarely on top of the one below, in any order. Installing an Optional SFP Transceiver Figure 3-5 Inserting an SFP Transceiver into a Slot The switch supports 1000BASE-SX and 1000BASE-LX, and 1000BASE-ZX...
Installing the Switch Connecting to a Power Source To connect a device to a power source: Insert the power cable plug directly into the socket located at the back of the device. Figure 3-6 Power Socket Plug the other end of the cable into a grounded, 3-pin, AC power source. Note: For international use, you may need to change the AC line cord.
Connecting to the Console Port Wiring Map for Serial Cable Table 3-1 Serial Cable Wiring Switch’s 8-Pin Null Modem PC’s 9-Pin Serial Port DTE Port 6 RXD (receive data) <---------------------------- 3 TXD (transmit data) 3 TXD (transmit data) -----------------------------> 2 RXD (receive data) 5 SGND (signal ground) ------------------------------ 5 SGND (signal ground) No other pins are used.
Chapter 4: Making Network Connections Connecting Network Devices The SMC8126PL2-F is designed to interconnect multiple network segments (or collision domains). It can be connected to network cards in PCs and servers, as well as to hubs, switches or routers. It may also be connected to devices using optional SFP transceivers.
Making Network Connections Connecting to PCs, Servers, Hubs and Switches Attach one end of a twisted-pair cable segment to the device’s RJ-45 connector. Figure 4-1 Making Twisted-Pair Connections If the device is a PC card and the switch is in the wiring closet, attach the other end of the cable segment to a modular wall outlet that is connected to the wiring closet.
Fiber Optic SFP Devices Equipment Rack (side view) Network Switch w it it c h 10 /1 0 0 6 7 2 4 L 3 ES4524C Punch-Down Block Patch Panel Wall Figure 4-2 Network Wiring Connections Fiber Optic SFP Devices An optional Gigabit SFP transceiver (1000BASE-SX, 1000BASE-LX or 1000BASE-ZX) can be used for a backbone connection between switches, or for connecting to a high-speed server.
Making Network Connections Nota: Cuando seleccione un dispositivo SFP de fibra óptica, y teniendo en cuenta la seguridad, asegúrese de que el mismo pueda operar a una temperatura que no sea mayor que la temperatura máxima recomendada de operación del producto. Se deberá...
Connectivity Rules 1000BASE-T Cable Requirements All Category 5 UTP cables that are used for 100BASE-TX connections should also work for 1000BASE-T, providing that all four wire pairs are connected. However, it is recommended that for all critical connections, or any new cable installations, Category 5e (enhanced Category 5) or Category 6 cable should be used.
Making Network Connections 10 Mbps Ethernet Collision Domain Table 4-6 Maximum Ethernet Cable Length Type Cable Type Maximum Length Connector 10BASE-T Twisted Pair, Categories 3, 4, 5 or better 100 m (328 ft) RJ-45 100-ohm UTP Cable Labeling and Connection Records When planning a network installation, it is essential to label the opposing ends of cables and to record where each cable is connected.
Appendix A: Troubleshooting Diagnosing Switch Indicators Table A-1 Troubleshooting Chart Symptom Action Power LED is Off • Check connections between the switch, the power cord, and the wall outlet. • Contact your dealer for assistance. Power LED is Amber • Internal power supply or RPU has failed. System is being powered by connected RPU.
Troubleshooting Installation Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (such as the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly.
Appendix B: Cables Twisted-Pair Cable and Pin Assignments For 10/100BASE-TX connections, the twisted-pair cable must have two pairs of wires. For 1000BASE-T connections the twisted-pair cable must have four pairs of wires. Each wire pair is identified by two different colors. For example, one wire might be green and the other, green with white stripes.
Cables Table B-1 10/100BASE-TX MDI and MDI-X Port Pinouts MDI Signal Name MDI-X Signal Name Transmit Data plus (TD+) Receive Data plus (RD+) Transmit Data minus (TD-) Receive Data minus (RD-) Receive Data plus (RD+) Transmit Data plus (TD+) Receive Data minus (RD-) Transmit Data minus (TD-) 4,5,7,8 Not used...
Twisted-Pair Cable and Pin Assignments You must connect all four wire pairs as shown in the following diagram to support Gigabit Ethernet connections. EIA/TIA 568B RJ-45 Wiring Standard 10/100BASE-TX Crossover Cable White/Orange Stripe Orange White/Green Stripe End A End B Blue White/Blue Stripe Green...
Cables Cable Testing for Existing Category 5 Cable Installed Category 5 cabling must pass tests for Attenuation, Near-End Crosstalk (NEXT), and Far-End Crosstalk (FEXT). This cable testing information is specified in the ANSI/TIA/EIA-TSB-67 standard. Additionally, cables must also pass test parameters for Return Loss and Equal-Level Far-End Crosstalk (ELFEXT).
Page 53
Fiber Standards Table B-3 Fiber Standards ITU-T Description Application Standard G.653 Dispersion-Shifted Fiber Longer spans and extended reach. Optimized for operation in the region Single-mode, 9/125-micron core from 1500 to 1600-nm. G.654 1550-nm Loss-Minimized Extended long-haul applications. Optimized for high-power FiberSingle-mode, 9/125-micron core transmission in the 1500 to 1600-nm region, with low loss in the 1550-nm...
Specifications AC Input 100 to 240 V, 50-60 Hz, 8.0A Power-over-Ethernet Maximum Output Voltage: 50-57 VDC; Maximum Output Current: Ports 1-4: -48 VDC, 600 mA (set by software; default value 350 mA) Ports 5-24: -52 VDC, 350 mA Power Supply Internal, auto-ranging transformer: 100 to 240 V AC, 50 to 60 Hz External, supports a 14-pin connection for a redundant power supply Power Consumption...
Page 61
Glossary 10BASE-T IEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3, 4, or 5 UTP cable. 100BASE-TX IEEE 802.3u specification for 100 Mbps Fast Ethernet over two pairs of Category 5 or better UTP cable. 1000BASE-LX IEEE 802.3z specification for Gigabit Ethernet over two strands of 50/125, 62.5/125 or 9/125 micron core fiber cable.
Page 62
Glossary CSMA/CD CSMA/CD (Carrier Sense Multiple Access/Collision Detect) is the communication method employed by Ethernet, Fast Ethernet, or Gigabit Ethernet. End Station A workstation, server, or other device that does not forward traffic. Ethernet A network communication system developed and standardized by DEC, Intel, and Xerox, using baseband transmission, CSMA/CD access, logical bus topology, and coaxial cable.
Page 63
Glossary IEEE 802.3z Defines CSMA/CD access method and physical layer specifications for 1000BASE Gigabit Ethernet. (Now incorporated in IEEE 802.3-2005.) LAN Segment Separate LAN or collision domain. Light emitting diode used for monitoring a device or network condition. Local Area Network (LAN) A group of interconnected computer and support devices.
Page 64
Glossary Transmission Control Protocol/Internet Protocol (TCP/IP) Protocol suite that includes TCP as the primary transport protocol, and IP as the network layer protocol. Unshielded twisted-pair cable. Virtual LAN (VLAN) A Virtual LAN is a collection of network nodes that share the same collision domain regardless of their physical location or connection point in the network.