<COMMAND SIN>
Get/Set System Info
Controller → Radio
SIN,[INDEX][\r]
SIN,[INDEX],[NAME],[QUICK_KEY],[HLD],[LOUT],[DLY],[RSV],[RSV],[RSV],[RSV],
[RSV],[START_KEY],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[NUMBER_TAG],
[AGC_ANALOG],[AGC_DIGITAL],[P25WAITING][\r]
Radio → Controller
SIN,[SYS_TYPE],[NAME],[QUICK_KEY],[HLD],[LOUT],[DLY],[RSV],[RSV],[RSV],[RSV],
[RSV],[REV_INDEX],[FWD_INDEX],[CHN_GRP_HEAD],[CHN_GRP_TAIL],[SEQ_NO],
[START_KEY],[RSV],[RSV],[RSV],[RSV],[RSV], [NUMBER_TAG],[AGC_ANALOG],
[AGC_DIGITAL],[P25WAITING],[PROTECT],[RSV][\r]
SIN,OK[\r]
[INDEX]
[SYS_TYPE]
CNV
MOT
EDC
EDS
LTR
P25S
P25F
[NAME]
[QUICK_KEY]
[HLD]
[LOUT]
[DLY]
[REV_INDEX]
[FWD_INDEX]
[CHN_GRP_HEAD]
[CHN_GRP_TAIL]
[SEQ_NO]
[START_KEY]
[NUMBER_TAG]
[AGC_ANALOG]
[AGC_DIGITAL]
[P25WAITING]
[PROTECT]
[RSV]
Get/Set System Information.
The scanner returns only "," to punctuate for parameters which are not
appropriate the system type.
In set command, the scanner neglects the parameters that are not appropriate
the system type.
In set command, only "," parameters are not changed.
The set command is aborted if any format error is detected.
This command is only acceptable in Programming Mode.
When the system protect bit is ON, except [SYS_TYPE], [NAME], [REV_INDEX],
[FWD_INDEX], [CHN_GRP_HEAD], [CHN_GRP_TAIL], other parameters will be send as
a reserve parameter in the Radio -> Controller command.
: System Index
: System Type
: CONVENTIONAL
: MOTOROLA TYPE
: EDACS Narrow / Wide
: EDACS SCAT
: LTR
: P25 STANDARD
: P25 One Frequency TRUNK
: Name
: Quick Key
: System Hold Time
: Lockout
: Delay Time
: Reverse System Index of the Scan Setting
: Forward System Index of the Scan Setting
: Channel Group Index Head of the conventional system
or Site Index Head of the Trunked System
: Channel Group Index Tail of the conventional system
or Site Index Tail of the Trunked System
: System Sequence Number
: Startup Configuration Key
: Number tag
: AGC Setting for Analog Audio
: AGC Setting for Digital Audio
: P25 Waiting time
: Protect bit Status
: Reserve Parameter
238
(max.16char)
(0-99/.(dot) means none)
(0-255)
(0:Unlocked / 1:Lockout)
(-10,-5,-2,0,1,2,5,10,30)
(1 - 500)
(0-9/.(dot) means none)
(0-999 / NONE)
(0:OFF / 1:ON)
(0:OFF / 1:ON)
(0,100,200, .... , 900,1000)
(0:OFF / 1:ON)
* This is always only ",".