Parameter Assignment For Measurement Modes - Siemens SIMATIC ET 200S Operating Instructions Manual

Hide thumbs Also See for SIMATIC ET 200S:
Table of Contents

Advertisement

1Count24V
2.7 Measurement Modes
2.7.12

Parameter Assignment for Measurement Modes

Introduction
You can use either of the following to assign parameters for the 1Count24V:
● STEP 7 V5.3 SP2 or later
● A GSD file (http://www.automation.siemens.com/csi/gsd)
Parameter List for Measuring Modes
Table 2- 22
Parameter List for Measuring Modes
Parameter
Enable
Group diagnostics
Response to failure of the higher-level controller
Response to CPU/master STOP
Encoder parameters
Signal evaluation A, B
Encoder and input filter
- At count input (track A)
- At direction input (track B)
- At digital input DI
Sensor A, B, DI
Direction input B
Output parameters
Diagnostics DO1
1
Function DO1
Substitute value DO1
82
Value Range
Disable/enable
Turn off DO1/
Continue working mode/
DO1 substitute a value/
DO1 keep last value
Pulse and direction/
Rotary encoder (single)
2.5 µs/25 µs
2.5 µs/25 µs
2.5 µs/25 µs
24V P switch, normal mode/
24V M switch
Normal/Inverted
Off/on
Output/
Outside the limits/
Under the low limit/
Over the high limit
0/1
Default
Disable
Turn off DO1
Pulse and Direction
2.5 µs
2.5 µs
2.5 µs
24V P switch, normal mode
Normal
Off
Output
0
Technological Functions