This device is intended for operation in the electromagnetic environment
given below. The user of the device should ensure that it is used in such
an environment.
Resistance to
Jamming Test
Discharge of
static electricity
in accordance
with IEC 61000-
4-2
Fast transient
electrical distur-
bance variables
/ bursts in accor-
dance with IEC
61000-4-4
Impulse volt-
ages (surges) in
accordance with
IEC 61000-4-5
Voltage break-
throughs, short
term interrup-
tions and varia-
tions in the
voltage supplied
in accordance
with IEC 61000-
4-11
Magnetic field at
the supply fre-
quency (50/60
Hz) in accor-
dance with IEC
61000-4-8
Note: U
is the alternating voltage.
r
2321 E EN 20130722
IEC 60601
Level of
Test Level
Agreement
+ 6 kV contact
+ 6 kV contact
discharge
discharge
+ 8 kV air dis-
+ 8 kV air dis-
charge
charge
+ 2 kV for net-
+ 2 kV for net-
work leads
work leads
+ 1 kV for entry
+ 1 kV for entry
and outlet leads
and outlet leads
+ 1 kV push-pull
+ 1 kV push-pull
voltage
voltage
+ 2 kV common
+ 2 kV common
mode voltage
mode voltage
< 5% U
r
(> 95% break-
(> 95% break-
through of U
)
through of U
r
for ½ period
for ½ period
40% U
(> 60%
r
breakthrough of
breakthrough of
U
) for 5 periods
U
r
70% U
(30%
r
breakthrough of
breakthrough of
U
) for 25 peri-
U
r
ods
ods
< 5% U
(95%
r
breakthrough of
breakthrough of
U
) for 5 s
U
r
3 A/m
3 A/m
Electromagnetic Environ-
ment Guidelines
Floors should consist of
wood, concrete or ceramic
tiles. The relative humidity
must be at least 30%, if the
floor is made of synthetic
material.
The quality of the voltage
supplied should correspond
to a typical commercial or
clinical environment.
The quality of the voltage
supplied should correspond
to that of a typical commer-
cial or clinical environment.
The quality of the voltage
< 5% U
r
supply should correspond to
that of a typical commercial
)
r
or clinical environment.
If the user wants the device
40% U
(> 60%
r
to work continuously, even
when the energy supply is
) for 5 periods
r
interrupted, it is recom-
70% U
(30%
r
mended to use an energy
supply free of interruptions
) for 25 peri-
r
or a battery.
< 5% U
(95%
r
) for 5 s
r
Magnetic field at the net-
work frequency should cor-
respond to the typical values
as they are in a commercial
and clinical environment.