Advertisement

Quick Links

HealthCare
Order-No.: DD+DIS014.02E
*1UT4741*
1 Piece UT474 MA1
th
4
Edition
This documentation is separately available. Order No: DD+DIS014.02E
printed in Germany 01 / 2002
ADC Compact
Type 5145 / 100/101/140
Type 5145 / 200/201/240
ADC Compact
Digitizer
Type 5145 / 100/101/140
Type 5145 / 200/201/240
Base: VME
Maintenance

Advertisement

Table of Contents
loading

Summary of Contents for AGFA 5145

  • Page 1 HealthCare Maintenance Order-No.: DD+DIS014.02E *1UT4741* ADC Compact Type 5145 / 100/101/140 1 Piece UT474 MA1 Type 5145 / 200/201/240 Edition ADC Compact Digitizer Type 5145 / 100/101/140 Type 5145 / 200/201/240 Base: VME This documentation is separately available. Order No: DD+DIS014.02E...
  • Page 2 The CE Declaration (CE Conformity) becomes invalid if the product is changed without explicit consent of the manufacturer! This applies to all parts, not only to safety elements. We reserve the right to technical changes Section 12 ADC Compact Edition 2, Revision 8 (Type 5145 / 100/101/140/200/201/240)
  • Page 3: Table Of Contents

    Checking the Image Quality........12 Test Cycles................12 Exposure of a Flatfield ............12 Evaluation of a Flatfield ............15 Completion of Maintenance ........16 Maintenance Checklist Edition 2, Revision 8 ADC Compact Section 12 / I (Type 5145 / 100/101/140/200/201/240)
  • Page 4: Safety

    · If you don't operate the ADC Compact correctly or if you don't have it serviced correctly, Agfa-Gevaert is not liable for resulting disturbances, damages or injuries. · When installing the ADC Compact, care must be taken to ensure that there is either a mains plug or an all-cable disconnecting device in the internal installation fitted near the ADC Compact and that it is easily accessible.
  • Page 5: General Information

    "must" maintenance points. Maintenance Frequency The maintenance has to be carried out: · every 15.000 cycles or · every 6 month Required Time approximately 3 h Section 12 / 2 ADC Compact Edition 2, Revision 8 (Type 5145 / 100/101/140/200/201/240)
  • Page 6: Required Tools

    CM+9.0450.6558.0 2 x Erasure lamp, 1000 W CM+9.0450.6559.0 1 x Erasure lamp, 2000 W CM+9.5145.9100.0 2 x Roller (at cassette unit) CM+9.9576.1801.0 1 x Air filter Edition 2, Revision 8 ADC Compact Section 12 / 3 (Type 5145 / 100/101/140/200/201/240)
  • Page 7: Maintenance Step By Step

    2.2 Throughput For throughput most important are the cycles per day. They usually count between 50 and 200. Section 12 / 4 ADC Compact Edition 2, Revision 8 (Type 5145 / 100/101/140/200/201/240)
  • Page 8: Visual Check

    (1) Clear the infocounters to refresh relative counters. 3.1.5 Visual Check · Flashlight (1) Check overall condition of the machine – outside and inside – for obvious changes or damage. Edition 2, Revision 8 ADC Compact Section 12 / 5 (Type 5145 / 100/101/140/200/201/240)
  • Page 9: Inside

    (1) Open the doors of the digitizer while the machine is switched (2) As soon as the left door is opened only a little all assemblies must be deenergized. 514512AL.CDR Figure 3 Section 12 / 6 ADC Compact Edition 2, Revision 8 (Type 5145 / 100/101/140/200/201/240)
  • Page 10: Vme Rack

    (4) Dust the VME Rack itself, the housing of the rack and all fan-grids. Handle the cables with care! Danger of damage by unplugging and Figure 6 plugging. Edition 2, Revision 8 ADC Compact Section 12 / 7 (Type 5145 / 100/101/140/200/201/240)
  • Page 11: Scan Unit

    (3) Exchange suction cups once a year. (4) In case of vacuum problems, check the suction cups by bending up the edges (check for tears) and replace if necessary. Figure 8 Section 12 / 8 ADC Compact Edition 2, Revision 8 (Type 5145 / 100/101/140/200/201/240)
  • Page 12: Erasure Unit

    2 x 1000 W lamps (CM+9.0450.6558.0) · 1 x 2000 W lamps (CM+9.0450.6559.0) (1) Remove the complete Erasure Unit by following the sequence and arrows in figure beside. Figure 11 Edition 2, Revision 8 ADC Compact Section 12 / 9 (Type 5145 / 100/101/140/200/201/240)
  • Page 13 Do not touch the lamps with your bare fingers! Use a soft cloth to insert the lamp. 514512cx.cdr Figure 12 (7) Re-insert the Erasure unit. Section 12 / 10 ADC Compact Edition 2, Revision 8 (Type 5145 / 100/101/140/200/201/240)
  • Page 14: Cassettes

    Visual Check (1) Check if there are scratches on the surface. (2) Check if edges are loose as an indication for mechanical problems at IP transport. Edition 2, Revision 8 ADC Compact Section 12 / 11 (Type 5145 / 100/101/140/200/201/240)
  • Page 15: Checking The Image Quality

    <Send flatfield> <Calibration pattern> <Banding pattern> Print the flat fields "Calibration" and "Banding" via the Processing Station (window setting of 0.6, without changing the level setting). Section 12 / 12 ADC Compact Edition 2, Revision 8 (Type 5145 / 100/101/140/200/201/240)
  • Page 16 In the <Sub-examination> list, click <Flat field>. · Confirm the Exposure class <200>. Make sure that the outlined areas are filled in as shown in the example. Edition 2, Revision 8 ADC Compact Section 12 / 13 (Type 5145 / 100/101/140/200/201/240)
  • Page 17 (4) Insert the cassette into the digitizer and print the image on a printer with a window setting of 0.6 without changing the level setting. Figure 14 Section 12 / 14 ADC Compact Edition 2, Revision 8 (Type 5145 / 100/101/140/200/201/240)
  • Page 18: Evaluation Of A Flatfield

    Fine sharp white or gray lines in fast scan direction on the flat field (see beside). · Check diagnostic images. If there are still unacceptable effects please contact the Support Center. Figure 16 Edition 2, Revision 8 ADC Compact Section 12 / 15 (Type 5145 / 100/101/140/200/201/240)
  • Page 19: Completion Of Maintenance

    (2) Make a backup of the system on floppy (3) Inform the customer about what was done during the maintenance and which repairs need to be done in next future. Section 12 / 16 ADC Compact Edition 2, Revision 8 (Type 5145 / 100/101/140/200/201/240)
  • Page 20 AGFA and the Agfa-Rhombus are trademarks of Agfa-Gevaert AG, Germany Herausgegeben von / Published by / Edité par / Pubblicato da / ../ Editado por Agfa-Gevaert AG Fototechnik Tegernseer Landstraße 161 D - 81539 München Printed in Germany / Imprimé en Allemagne /...
  • Page 21 HealthCare Maintenance Checklist Order-No.: DD+DIS014.02E ADC Compact Type 5145 / 100/101/140 Type 5145 / 200/201/240 Work Instruction for order no. Cycles The maintenance has to be carried out: · Every 6 months or every 15 000 cycles Maintenance must be carried out according to the maintenance instructions, see section 12 of your Service Documentation.
  • Page 22: Maintenance Checklist

    Done General · Confirm the maintenance · Make a backup of the system on floppy · Inform the customer about maintenance and which repairs are necessary Maintenence Checklist ADC Compact Edition 2, Revision 8 Page 2 (Type 5145 / 100/101/140/200/201/240)
  • Page 23 DD+DIS014.02E Maintenance Checklist Remarks: ........................................................................................................................................................................................................................................... Date / Signature Service Technician Customer Edition 2, Revision 8 ADC Compact Maintenence Checklist (Type 5145 / 100/101/140/200/201/240) Page 3...

This manual is also suitable for:

100101140200201240

Table of Contents