Page 68
Chapter 4, SteamCraft 10 Service Manual
This troubleshooting guide includes a list of symptoms that
may be encountered during routine operation and maintenance.
The first column on the left (problem) describes these
symptoms. The second column lists possible causes for the
problem listed in column one. The third column lists remedies
and or references for the problems and causes in columns one
and two. The causes and remedies are listed in the order they
should be checked, with the least costly
PROBLEM
Switch light does not turn on when
ON/OFF switch is pressed on.
Power ON and steam generator does not
fill
ON/OFF switch light on and steamer does
not make any steam in manual or timed
mode.
Abnormal amount of steam coming
from drain.
Printed 3/93
OPERATOR'S TROUBLESHOOTING GUIDE
POSSIBLE CAUSE
Power turned off at main dis connect
switch-
Water supply to steamer shut off.
Water line strainer is clogged.
Water supply to steamer shut off.
Water line strainer is clogged.
Gas models only — gas supply valve
closed.
Electric models only — heating
elements covered with scale.
Electric models only — heating
elements damaged.
Inoperative controls or solenoid-
Hot water instead of cold water
connected to condenser fitting-
Water supply to condenser turned off.
Condenser water line strainer is
clogged.
Water supply line to the condenser
blocked, broken, or leaking.
Inoperative condenser solenoid-
Inoperative controls -
Models 24-CGA-10, 24CGP-10, 24-CEA-10, 24-CEP-10
and easiest to repair listed first. The third column also refers to
notes that are grouped at the end of the troubleshooting guide-
Refer to these notes when instructed to do so. Do not try to
correct a problem that requires an authorized service
representative as this may adversely affect warranty coverage.
REMEDY/REFERENCE
Turn on power at main disconnect switch.
Open water supply valves.
Clean water supply strainer.
Open water supply valves.
Clean water supply strainer.
Turn OFF unit and open gas supply valve.
Descale steam generator with USDA approved
descaler.
See note #1.
See note # 1.
Make proper connections. See page 24.
Open water supply valve.
Clean out condenser water supply strainer.
Repair or replace water supply line. See note
#1.
Replace solenoid. See note #1.
Turn off electricity at main disconnect switch.
See note #1.