Cleveland SteamCraft 10 Service Manual page 115

Convection steamer
Table of Contents

Advertisement

Models 24-CGA-10, and 24-CEA-10
Open the cooking compartment door for a few minutes to cool the compartment.
Set the timer of the upper control panel for 5-minutes and press the START/STOP key.
IT:4-7 Does the timer begin to count down after the cooking compartment reaches cooking
temperature?
IT:4-8 Does the timer START/STOP key pause and restart the timer countdown?
IT:4-9 Does the timer CLEAR key zero the timer?
Set the timer of the upper control panel for 5-minutes and press the START/STOP key.
Cleveland Range, Inc.
SteamCraft 10 Service Manual, Chapter 6
NOTE: The compartment should be below cooking temperature to start
testing.
NOTE: After the cooking time is set and the START/STOP Key is
pressed. the compartment thermostat switch prevents timer countdown
until the compartment reaches cooking temperature. This switch is
normally open, closes at cooking temperature, and re-opens when the
compartment drops. below cooking temperature
Failure of the compartment thermostat or the electronic timer will prevent timer
countdown.
1. Check the compartment thermostat switch according to component test CT:18.
2. Check the electronic timer module according to component test CT:17.
NOTE: Once the timer countdown has begun, it can be stopped by pressing
the timer START/STOP key. Press this key once to pause the countdown
and again to restart the countdown.
Replace the timer.
NOTE: Pressing the timer CLEAR key when th
returns the cooking time setting zero (00:00).
Replace the timer.
NOTE: After performing test IT:4-7, the Toner is zeroed. A cooking time must be
set to continue testing.
Page 109
.
countdown is paused
e
Printed 3/93