Models 24-CGA-10, and 24-CEA-10
Figure 6-16. Float Assembly and Components
Cleveland Range, Inc.
24-CEA-10
5. Set the ON/OFF switch to the ON position, and check the voltmeter readings with
6. Check for 115/120 VAC from the TIMED/MANUAL switch orange wire
7. About one minute after the fill solenoid valve opens, the water begins to fill the
SteamCraft 10 Service Manual, Chapter 6
no water in the float cylinder.
• If the meter reads 115/120 VAC, continue this procedure with step 7.
• If the meter reads 0 VAC, continue this procedure with step 6.
to the ON/OFF switch white/black wire connection.
• If the meter does not read 115/120 VAC, the fault is not in the float assembly.
a. Test the ON/OFF switch.
b. Test the TIMED/MANUAL switch.
c. Test the contactor for an open coil.
• If the meter reads 115/120 VAC, either the float or the float wiring circuit is
faulty.
a. Check the wiring between the TIMED/MANUAL switch, the float, the
contactor, and the ON/OFF switch for continuity, and secure connections.
Replace or repair faulty wiring and connections.
b. If the wiring and connections are good, the float assembly is faulty. Replace
the float assembly.
float cylinder. Check the bottom of the cylinder.
• If water begins to fill the float cylinder, continue this procedure with step 9.
• If water does not begin to fill the float cylinder, continue this procedure with
step 8.
Figure 6-17. Float Assembly and Components
24-CGA-10
Page 129
Printed 3/93