Cleveland SteamCraft 10 Service Manual page 121

Convection steamer
Table of Contents

Advertisement

Models 24-CGA-10, and 24-CEA-10
PHASE 2 TESTING
Set the ON/OFF switch to the ON position.
IT:2-1 Does the red ON/OFF switch indicator light?
IT:2-2 Does water start filling the steam generator?
Cleveland Range, Inc.
SteamCraft 10 Service Manual, Chapter 6 Page 115
This phase of testing pertains to the components associated with preheat functions.
After completing Phase 1 Testing, verify that the following conditions are set to
start Phase 2 testing:
• The right side and front access panel are removed and the float
assemblies, relays and contactors are clearly visible.
• The Main Disconnect Switch is in the ON position and the 3-minute
blowdown cycle has stopped.
• The ON/OFF power switch is in the OFF position.
• Both upper and lower compartment TIMED/MANUAL switches are in
the TIMED position.
• Both upper and lower compartment timers are set for zero minutes.
a. For Key Pad Control Panels: The timer display is blank while the
ON/OFF switch is set to OFF. If the timer is not zeroed (00:00) when
power is turned on, press and hold the CLEAR key on the key pad
control panel until the timer is zeroed.
b. For Dial Tuner Control Panels: Turn the dial counter clockwise until it
points to the 0 mark.
Simultaneous Testing.
Examine the components of th
generator groups simultaneously during Phase 2.
NOTE: The red ON/OFF switch light turns on. The fill valve opens and the
drain valve closes. Water begins to fill the steam generator. After a few
minutes, water appears in the bottom of the float cylinder as the water level
in the steam generator rises.
Test the ON/OFF switch according to component test CT:5.
Four possible malfunctions can prevent water from filling the steam gener-
ator during the preheat and steaming cycle.
• The plumbing between the drain valve and fill valve, or drain valve and
steam generator is blocked.
• The operational water float (upper switch) is malfunctioning.
• The fill solenoid valve is blocked or malfunctioning.
• The 3-way drain valve is blocked or malfunctioning.
1. Check the fill solenoid valve and adjoining plumbing for blockage.
2. Check the drain solenoid valve and adjoining plumbing for blockage.
upper and lower compartment and steam
e
Printed 3/93