Cleveland SteamCraft 10 Service Manual page 149

Convection steamer
Table of Contents

Advertisement

Models 24-CGA-10, and 24-CEA-10
Cleveland Range, Inc.
SteamCraft 10 Service Manual, Chapter 6
Figure 6-41. Upper and Lower Compartment Contactors
24-CEA-10
b. Test the high temperature limit switch.
c. Test the float low level switch.
d. Test the TIMED/MANUAL switch.
5. Set the voltmeter to the 500 VAC scale. Refer to Figure 6-41, and check
the voltage across the contact pairs.
• If the meter reads 230 VAC across one or more contact pairs, replace
the heater contactor.
• If the meter reads 0 VAC across all contact pairs, the fault is not in the
heater contactor.
a. Check the wires and connections from the contact pairs to the
heater elements for continuity and secure connections. Replace or
repair faulty wiring and connections.
b. Check the wires and connections from the terminal block to the
contacts for continuity and secure connections. Replace or repair
faulty wiring and connections.
c. Test heater elements.
Page 143
Printed 3/93