Models 24-CGA-10, 24-CGP-10. 24-CEA-10, 24-CEP-10
1 . For each unit, the installer must provide a ground con-
nection and a separate fused disconnect switch.
2. The Product Identification Plate, located in the lower right
corner of the left side panel, specifies the electric power
and gas utility requirements.
3. A manual shut off valve and a drip leg must be installed
between the main gas supply and the steamer supply
lines- Bleed air from the gas line at the fitting closest to
the internal automatic gas valve. Refer to Figure 2-14 for
the recommended component arrangements.
4. Never exceed 14" water column (1/2 psi) gas pressure. If
the gas supply pressure exceeds 14" water column, a
pressure regulating valve must be installed in the gas
supply plumbing to reduce the gas pressure to less than
14" water column.
5. The unit must have a cold water supply, NOT HOT. The
water supply must meet the quality requirements of
Table 2-2, and the pressure requirements on page 16.
6. A SteamerGard filtering system is recommended when
water quality does not meet the Table 2-2 requirements,
SteamCraft 10 Service Manual Chapter 2
INSTALLATION DIAGRAM NOTES
7. Run a single water line between the main cold water supply
and the tee. The two separate steam generator and
condenser/blowdown supply lines are relatively short.
8. A manual shut off valve must be installed between the main
water supply and the steamer supply lines- Refer to Figure
2-10 or 2-11 for recommended component arrangements.
9. The drain line must have a gravity flow away from the
steamer, and must not be connected to the drain lines of any
other equipment.
10. The drain line must be free air vented. If the line empties
into a floor drain, there must be a one inch minimum
clearance between me drain line and the floor drain
openings- The floor drain must not be located under the
body of the unit.
11. To maintain proper operation and full warranty coverage,
the unit must be level from to back and side 10 side.
12. The flue at the back of the gas-fired units must be ventilated
as specified by local and national codes
Figure 2-1. Schematic Installation Diagram