212
SteamCraft 10 Service Manual, Chapter 8
MANUAL VALVE KNOB
Manual valve knob is a two position On-Off type.
To Turn On - Rotate knob clockwise or counterclock-
wise to line up "ON" on knob with indicator on cover
casting.
To Turn Off – Rotate knob clockwise or counterclock-
wise to line up "OFF" on knob with indicator on cover
casting.
To prevent electrical shock and/or equipment damage,
disconnect electrical power to system at main fuse or
circuit breaker box until installation is complete.
All wiring should be installed in accordance with local
and nation electrical codes and ordinances.
Always check that the elctrical power supply used
agrees with the voltage and frequency shown on the
gas control.
PRESSURE REGULATOR
The regulated outlet pressure, both Lo and Hi outlet,
has been calibrated at factory. Although additional
adjustment should not be necessary, the full outlet
regulator pressure can be field adjusted for outlet
pressure of 3.0" to 5.0" W.C. for Natural gas and 9.0" to
12.0" W.C. for LP. Do not force adjustment socket set
screw beyond these limits. If a valve has been factory
adjusted for 3.0" to 5.0" W.C. range, it cannot be field
adjusted outside this range. This is also true for valve
adjust to the 9.0" to 12.0" W.C. range for LP.
1. Turn off power to system at main fuse or circuit
breaker.
2. Attach a manometer to the outlet pressure tap of
the gas valve.
3. Turn on power to the system and energize valve.
4. Remove adjustment seal screw (see fig. 5).
5. To DECREASE outlet pressure, turn the adjusting
socket set screw (beneath the adjustment seal
screw) counterclockwise. To INCREASE outlet
pressure, turn the adjusting socket set screw
clockw ise. Adjust regulator until pressure shown
on manometer matches the pressure specified on
the appliance rating plate.
6. Replace the cover screw. Cycle the valve two or
three times to verify regulator setting.