Models 24-CGA-10, 24-CGP-10, 24-CEA-10, 24-CEP-10
Figure 2-6. Drain Layout and Connections
Figure 2-7. Access Panel Removal
Page 21 SteamCraft 10 Service Manual, Chapter 2
DEATH, INJURY, AND EQUIPMENT DAMAGE
could result from improper installation of the drain
outlet lines.
Improper installation of these lines could void the
SteamCraft 10 Steamer warranty. The following
restrictions are critical to the safety of personnel and
equipment, and must not be violated under any
circumstances.
Do not connect the drain line into PVC pipe, or any
other drain material that cannot sustain 180° F.
Do not connect drains from any other equipment to the
SteamCraft 10 Steamer drain line.
Do not connect the drain outlet extension line directly
to a floor drain or sewer line.
1. The drain lines must be installed in compliance with local, state, and national
utility, construction and sanitation codes; the most prominent of which are listed
in the Installation Policies section below
2. The floor drain receiving the hot condensate from the Steam Craft 10 must not be
located under the body of the unit. Steam rising from the drain up into the unit
body will adversely affect operation, cooling air ventilation. and may cause
corrosion on some of the electrical contacts. Improper location of this drain will
seriously reduce warranty coverage.
3. The total length of pipe and number of bend fittings required to reach the open
drain determines the pipe size used to extend the drain line to an open drain.
• If the drain outlet extension requires six feet or less of pipe, and no more than
two elbows are required, use 1.5-inch pipe and fittings.
• If the drain outlet extension requires six to twelve feet of pipe, or requires three
or more elbows, use 2-inch pipe and fittings.
4. The drain line must have a gravity flow from the Steam Craft 10 Steamer drain
outlet to the floor drain Do not install a trap in the drain line.
5. Free air venting requires a minimum of one inch clearance between the end of the
drain line and the top of the floor drain.
6. Do not connect the steamer drain to drains or plumbing of any other equipment. If
drains of two or more units are connected together.
• Low pressure can develop, causing an implosion and physical collapse of the
steamer.
• Drainage from another unit can flow back into a cooking compartment of the
steamer.
WARNING