KEY PAD CONTROL PANEL
SUMMARY
Figure 3-2. Key Pad Control Panel
Figure 3-3- Steam Generator Controls Pressure
Units Only
SteamCraft 10 Service Manual, Chapter 3
On atmospheric units, the ON/OFF switch both energizes the unit controls and
starts the water fill and steam generator preheating cycle. On pressurized units, the
ON/OFF switch energizes the unit controls and starts the water fill cycle. The
Steam switch starts the preheat and steam cycles.
Press switches with fingertips only. Do not use kitchen
utensils or anything sharp to operate the switches.
1. TIMER Display
This four-digit display indicates the minutes and seconds remaining in the count
down. The display reads from zero (00:00) to 99 minutes and 99 seconds (99:99).
It reads pause (PAUS) when the count down is halted either by the START/STOP
key or by the temperature compensating circuit.
2. Number Pad Keys
These keys set the number of minutes and seconds in the timer count down.
Pressing the number keys 1 2 3 4 in this sequence, sets the timer for 12 minutes
and 34 seconds (12:34).
3. START/STOP Key
This key starts and stops the timer. In TIMED mode the steaming functions are
linked to the timer. In MANUAL mode, the steaming functions are independent of
the timer.
4. CLEAR Key
This key resets the timer to zero (00:00) after it has been stopped. The timer must
be zeroed by pressing this key before a new time can be set
5. TIMED/MANUAL Switch
The TIMED/MANUAL switch selects the manual or timed operating mode.
• MANUAL (bottom) end of switch selects the manual mode.
• TIMED (top) end of the switch selects the timed mode.
6. ON/OFF switch - Atmospheric Models
The ON/OFF switch controls electric power to the steamer. The ON/OFF switch is
located below the upper cooking compartment controls and enables cooking in
both compartments.
• ON (top) end of switch energizes the steamer control panels. A red indicator on
the switch lights, and water fills the steam generator and heats to stand-by
temperature.
• OFF (bottom) end of switch rums the steamer control panel OFF. The red
indicator goes out, and the 3-minute blowdown cycle starts.
7. ON/OFF switch - Pressure Models Only
The ON/OFF switch controls electric power to the steamer. The ON/OFF switch is
located below the upper cooking compartment controls and enables cooking in
both compartments.
CAUTION