SteamCraft 10 Service Manual, Chapter 8
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING
OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY
DAMAGE.
The 36E96 Series D.B.I. & H.S.I. gas valve is
designed for use on automatic spark ignition systems
and hot surface application. It is equipped with a
redundant solenoid valve, a solenoid operated main
valve that controls gas glow to the main burner, a
pressure regulator to maintain a constant outlet
pressure for varying inlet pressures, a Lo-Hi feature
to permit two stage setting for lighting of main burner
and a two position knob for manual gas shut off.
A variety of models are available to suit voltage, pipe size,
and pressure regulation requirements.
Do not exceed the specification ratings.
All wiring must conform to local and national
electrical codes and ordinances.
This control is a precision instrument that should be
handled carefully. Rough handling or distorting
components could cause the controls to
malfunction.
Description
Precautions
Specifications
Installation
Main Piping Connections
Manual Valve Knob
System Wiring
Pressure Regulator Adjustment
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123
Printed 3/93
NOTE
CONTENTS
1
1
2
2
Models 24-CGA-10 and 24-CEA-10
Fig. 1
Do not use on circuits exceeding 30 volts.
Higher voltage will damage the control and
may cause shock or fire hazard
To prevent electrical shock and/or equipment
damage, disconnect electrical power to the
sys tem, at the main fuse or circuit box, until
installation is complete.
S hut off gas to main heating system until
installation is complete.
Do not short out terminals on gas valve or pri-
mary control to test. Short or incorrect wiring
can cause equipment damage property
damage. and/or personal injury.
This control is not intended for use in locations
where it may come in direct contact with water.
Suitable protection must be provided to shield
the control from exposure to water (dripping,
spraying, rain, etc.).
Printed in U.S.A.
DESCRIPTION
PRECAUTIONS
PART No. 37-5143A
9204