Cleveland SteamCraft 10 Service Manual page 127

Convection steamer
Table of Contents

Advertisement

Models 24-CGA-10, and 24-CEA-10
Open the cooking compartment door for a few minutes to cool the compartment.
Set the timer of the upper control panel for 5-minutes and press the START/STOP key.
IT:4-7 Does the timer begin to count down after the cooking compartment reaches cooking
temperature?
IT:4-8 Does the timer START/STOP key pause and restart the timer countdown?
IT:4-9 Does the timer CLEAR key zero the timer?
Set the timer of the upper control panel for 5-minutes and press the START/STOP key.
Cleveland Range, Inc.
SteamCraft 10 Service Manual, Chapter 6
NOTE: The compartment should be below cooking temperature to start
testing.
NOTE: After the cooking time is set and the START/STOP Key is
pressed. the compartment thermostat switch prevents timer countdown until
the compartment reaches cooking temperature. This switch is normally
open. closes at cooking temperature, and reopens when the compartment
drops below cooking temperature.
Failure of the compartment thermostat or the electronic timer will prevent
timer countdown.
1. Check the compartment thermostat switch according to component test
.
CT:18
2. Check th
electronic timer module according to component test
e
NOTE: Once the timer countdown has begun, it can be stopped by pressing
the timer START/STOP key. Press this key once to pause the countdown
and again to restart the countdown.
Replace the timer.
NOTE: Pressing the timer CLEAR key when the countdown is paused
returns the cooking time setting zero (00:00).
Replace the timer.
NOTE: After performing test IT:4-7, the Timer is zeroed. A cooking time
must be set to continue testing.
Check the electronic timer according to component test
Page 121
.
CT:17
.
CT:17
Printed 3/93