Cleveland SteamCraft 10 Service Manual page 215

Convection steamer
Table of Contents

Advertisement

Models24.CGA.10 and 24-CEA-10
SPECIFICATIONS
Type of Gas: Suitable for use with all gases.
Pressure Regulator Settings:
Nat. Gas -
Low Setting 1.0" to 5.0"
Factory Set
High Setting 3.0" to 5.0"
L.P. Gas -
Low Setting 3.0" to 12.0"
Factory Set
High Setting 9.0" to 12.0"
Pressure Rating: 14" W.C. (1/2 PSI) max.
Ambient Temperature: 0ºF to 175ºF
INSTALLATION
NEVER USE FLAME OR ANY KIND OF SPARKS TO
CHECK FOR GAS LEAKS - COULD CAUSE FIRE
All piping must comply with local codes, ordinances,
and/or national fuel gas codes.
MAIN PIPING CONNECTIONS
Failure to aim off electric or main gas supply to heating
system could cause personal Injury and/ or property
damage by shock, gas suffocation, fire, and/or
1. Turn off electrical power to the system at the fuse
box or circuit breaker. Also, turn off the main gas
supply.
Cleveland Range, Inc.
PIPE SIZES AVAILABLE
3/8" X 3/8" NPT Any Combination
3/8" x ¾" NPT Straight Through
½" x 3/8" NPT Any Combination
½" x ½" NPT Any Combination
½" x ¾" NPT Straight Through
AND/OR EXPLOSION.
explosion.
Figure 2. Piping Connections
SteamCraft 10 Service Manual, Chapters
1.0" PRESS. DROP CAPACITY
BTU/HR.
AGA STD. NAT. GAS
(1,000 BTU/CU. FT.)
75,000
75,000
100,00
140,000
140,000
2. If replacing an existing valve, disconnect all plumbing
and electrical connections from the old control.
3. The control may be installed in any orientation. The
arrow on the valve indicates the direction of gas flow
through the control.
4. You should use new pipe that is properly reamed and
free of burrs and chips. If you are using old pipe, be
sure it is clean and free of rust, scale, burrs, chips
and old joint compound.
5. Apply pipe joint compound (pipe dope) that is ap-
proved for all gases, only to the male threads of the
pipe joints. DO NOT apply compound to the first two
threads (see fig. 1 for typical piping
connections).
6. If you are using a vise or open-end wrench to hold
the valve while installing piping, do not tighten exces-
sively, as this may damage the valve.
7. See SYSTEM WIRING when making electrical con-
nections. After all gas and electrical connections are
completed, turn gas on and check for leak detection
solution or soap suds. Bubbles forming indicate a
leak. SHUT OFF GAS AND FIX ALL LEAKS
IMMEDIATELY.
211
LP GAS
(2,500 BTU/CU. FT.)
121,500
121,500
162,000
226,800
226,800
Printed 3/93