Cleveland SteamCraft 10 Service Manual page 33

Convection steamer
Table of Contents

Advertisement

Models 24-CGA-10, 24-CGP-10, 24-CEA-10, 24-CEP-10
5. Refer to the recommended plumbing layouts in Figures 2-10 and 2-11 and install
the water supply lines and fittings in accordance with all local and national
codes. Pay particular attention to the following requirements and
recommendations.
a. When installing a water supply system without a SteamerGard, Cleveland
Range recommends the plumbing layout illustrated in Figure 2-10. This is a
single water line from the main cold water supply to the tee just outside the
SteamCraft 10. The two separate lines from the tee to the steam generator and
condenser/blowdown connections are comparatively short.
b. When installing a water supply system with a SteamerGard. Cleveland Range
recommends the plumbing layout illustrated in Figure 2-11. Note the following
details:
• This is a single water line from the main cold water supply to the tee just
before the SteamerGard. The two separate and comparatively short lines
run from the tee to the SteamerGard intake connection and from the tee to
the SteamCraft 10 condenser/blowdown connec-tion.
• The water supply to the condenser connection can be untreated.
• The treated water supply connects to the steam generator fill connec -
tion.
Figure 2-11. Treated Water Supply Arrangement
SteamCraft 10 Service Manual, Chapter 2
Page 25