Control Command; Esc+A Data Send Start - SATO LC400e Series Programming Reference Manual

Hide thumbs Also See for LC400e Series:
Table of Contents

Advertisement

5. Control Command

5.1 Control
CL408e/412e
Printer
M-8485Se/90Se/60Se/59Se

5.1 ESC+A Data Send Start

Data Send Start
ESC
HEX Code
<1B>
16
Default Value
NIL
Valid Range and
When Power is Switched Off
Terms of
Valid Range within Items
Command
Valid Range between Items
[Function]
To specify Data Send Start.
[Format]
<A>
[Coding Example]
<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>
[Supplementary Explanation]
1.To show item starts, must be used at the beginning of the item.
2.Data Send Start Specification <A> and Data Send End Specification <Z> must be used as a pair.
[Point]
1.All of the command setting value excluded one portion of the system command will return to the default value.
2.Print motion is inactive when Data Send Start Specification <A> is not specified.
M-8400RVe
CL608e/612e
M-84Pro-2/3/6
LC408e/412e
A
Parameter
<41>
NIL
16
The set command is not maintained
The set command becomes invalid
The set command becomes invalid
M-5900RVe
M-10e
ESC+A
13