Esc+Rk Rfid Write - SATO LC400e Series Programming Reference Manual

Hide thumbs Also See for LC400e Series:
Table of Contents

Advertisement

5.6 Control
CL408e/412e
Printer
M-8485Se/90Se/60Se/59Se

5.6 ESC+RK RFID Write

RFID Write
ESC
HEX Code
<1B>
16
Default Value
b=0, c=0
Valid Range and
When Power is Switched Off
Terms of
Valid Range within Items
Command
Valid Range between Items
[Function]
To specify data to be written in RFID Tag
[Format]
<RK>a(,b)(,c),Dmm,n~n
●Parameter
a
{Tag Type Specification}
b
{RFID Tag Error Ignore Specification}omittable =
c
{Write Protector Specifcation}omittable
m
{Write Data Size Specification}
n
{Write Data}
[Coding Example 1] Record 13 byte of characters {4912345678904}on the Tag-it tag(omit b,c)
<A>
<V>50<H>50<BD>3020654912345678904
<RK>1,D13,4912345678904
<Q>2
<Z>
[Coding Example 2] Record 13 byte of characters {4912345678904}on the Tag-it tag, ignore 3 pieces of errors(omit c)
<A>
<V>50<H>50<BD>3020654912345678904
<RK>1,3,D13,4912345678904
<Q>2
<Z>
[Coding 3] Record 13 byte of characters {4912345678904}on the Tag-it tag, error ignore is not available, write protector is available.
<A>
<V>50<H>50<BD>3020654912345678904
<RK>1,0,1,D13,4912345678904
<Q>2
<Z>
M-8400RVe
CL608e/612e
M-84Pro-2/3/6
LC408e/412e
RK
Parameter
<52>
<4B>
a(,b)(,c),Dmm,n~n
16
16
The set parameter is not maintained
The set parameter becomes invalid
The set parameter becomes invalid
=
=
= valid range :
M-5900RVe
M-10e
ESC+RK
0 :
I-CODE(max 48 byte writable)
1 :
TAG-IT (max 32 byte writable)
0 :
No Specification when omission 0
1 :
With Specification
2~9 :
RFID Tag Error Ignore Specification Print Number
0 :
No Specification when omission 0
1 :
With Specification(valid only when a=1)
0~48(byte)(when it is a=1)
:
0~32(byte)(when it is a=2)
18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents