9.8 Barcode
CL408e/412e
Printer
M-8485Se/90Se/60Se/59Se
9.8 ESC+BC CODE93 Barcode
CODE93 Barcode
ESC
HEX Code
<1B>
16
Default Value
NIL
Valid Range &
When Power is Switched Off
Terms of
Valid Range within Items
Command
Valid Range between Items
[Function]
To specify CODE93 barcode.
[Format]
<BC>aabbbccn~n
● Parameter
a
{Thin Bar Width}
b
{Barcode Height}
c
{Data Digit Number}
n
{Print Data}
[Coding Example] Thin Bar Width:02, Barcode Height:120, Digit Number:12, Print Data:ABCD123456xy
<A>
<V>100<H>200<BC>0212012ABCD123456xy
<Q>2
<Z>
[Supplementary Explanation]
1.C/D is created automatically.
2.The maximum data input digit numbers is until 99 digits.
3.The data digit number and input data number must be the same.
4.It becomes error if input data number is not as same as data digit number.
M-8400RVe
CL608e/612e
M-84Pro-2/3/6
LC408e/412e
BC
Parameter
<42>
<43>
aabbbccn~n
16
16
The set parameter is not maintained
The set parameter becomes invalid
The set parameter becomes invalid
=
valid range
:
=
valid range
:
=
valid range
:
=
barcode data (refer to CODE93 code table)
M-5900RVe
M-10e
ESC+BC
01~12 (dot)
001~999 (dot)
01~99
100