5 Control Command

5.1 Control
5.1

ESC+A Start Code

Start Code
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifying the start of data transmission.
[Format]
<A>
[Coding Example]
<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>
[Supplementary Explanation]
1. Indicates the start of item and to be placed at the head of item.
2. Use <A> and End of Data Transmission <Z> as a pair of commands.
[Notes]
1. Setting value of all commands excluding a part of system commands will be set to default.
2. If this command is not specified, printing will not be performed.
A
Parameter
<41>
Nil
16
The set command is not maintained.
The set command becomes invalid.
The set command becomes invalid.
10