Esc+A3 Correction Pitch - SATO LC400e Series Programming Reference Manual

Hide thumbs Also See for LC400e Series:
Table of Contents

Advertisement

12.4 System
CL408e/412e
Printer
M-8485Se/90Se/60Se/59Se

12.4 ESC+A3 Correction Pitch

Correction Pitch
ESC
HEX Code
<1B>
16
Default Value
NIL
Valid Range &
When Power is Switched Off
Terms of
Valid Range within Items
Command
Valid Range between Items
[Function]
To specify the change of coordinate of the standard start point. Normally it is set at LCD advanced mode.
[Format]
<A3>VabbbbHcdddd
● Parameter
a
{V Correction Pitch Symbol}
b
{V Direction Correction (dot)}
c
{H Correction Pitch Symbol}
d
{H Direction Correction (dot)}
[Coding Example]
<A>
<A3>V10H10
<Z>
Start Point After Specified
[Supplementary Explanation]
1.Perform correction pitch arbitrarily, be aware when printing cannot be performed due to exceeding print valid area.
2.Perform correction pitch by using multiple lable format, be aware when all of the label format will be performed correction pitch.
[Point]
1. When print correction pitch is performing at the LCD advanced mode, correction pitch is specified at the correction pitch
specification <A3>, the value that is specified at the correction pitch specification <A3> will become valid.
2. Correction pitch value that is specified at the correction pitch specification <A3> will be registered at the LCD advanced
mode.Therefore, correction pitch value that is specified at correction pitch specification <A3> will be maintained even if printer
power is switched OFF.
M-8400RVe
CL608e/612e
M-84Pro-2/3/6
LC408e/412e
A3
Parameter
<41>
<33>
VabbbbHcdddd
16
16
The set parameter is maintained.
The set parameter is valid until the next specification is done.
The set parameter is valid until the next specification is done.
(omittable)
(omittable)
Start Point Before Specify
H
V
M-5900RVe
M-10e
ESC+A3
=
+, -
=
refer to next page table
=
+, -
=
refer to next page table
206

Hide quick links: