12.21 System
CL408e/412e
Printer
M-8485Se/90Se/60Se/59Se

12.21 ESC+TW Option Waiting Time

Option Waiting Time
ESC
HEX Code
<1B>
16
Default Value
aaa = 005
When the power switch is
Valid range and
OFF
term of
Valid range within items
command
Valid range between items
[Function]
Specifies waiting time for optional device
[Format]
<TW>aaa
●Parameter
aaa
[Waiting time]
[Coding Example] (waiting time = 1.5 seconds)
<A>
<TW>015
<Z>
[Supplementary Explanation]
1. This command specifies, in Tear-off mode, the waiting time between print completion and Tear-off motion.
2. The set parameter becomes valid soon after receiving the command and will be retained after power off.
3. When it switches to OFFLINE during the waiting time, it forces the printer to operate in Tear-off mode.
M-8400RVe
CL608e/612e
M-84Pro-2/3/6
TW
<54>
<57>
16
16
The set parameter is maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
=
Valid range: 005 to 200 (unit: 100ms)
M-5900RVe
M-10e
LC408e/412e
ESC+TW
Parameter
aaa
228