Omron Sysmac NJ-series User Manual page 500

Machine automation controller cpu unit built-in ethernet/iptm port
Hide thumbs Also See for Sysmac NJ-series:
Table of Contents

Advertisement

15 Troubleshooting
Connection status
General
Additional
Status
Status
(hex)
(hex)
01
0205
Error code returned from target:
There was a parameter error in the
frame used to open the connection.
01
0302
Error code generated by originator
or returned from target:
The tag data link's allowable band-
width (pps) was exceeded.
01
0311
Error code returned from target:
There was a parameter error in the
frame used to open the connection.
01
0312
Error code returned from target:
There was a parameter error in the
frame used to open the connection.
01
0315
Error code returned from target:
There was a parameter error in the
frame used to open the connection.
01
0316
Error code returned from target:
There was a parameter error in the
frame used to close the connection.
01
031C
Error code generated by originator:
Some other error occurred.
08
---
Error code returned from target:
There is no Forward Open or Large
Forward Open service in the target
device.
D0
0001
Error code generated by originator:
The connection operation is
stopped.
D0
0002
Error code generated by originator:
The connection is being opened
(opening processing in progress).
15-62
Source of error
Configuration 1
This error does not
occur.
Check the connec-
tion settings (number
of connections and
RPI) at the origina-
tor and target.
This error does not
occur.
This error does not
occur.
This error does not
occur.
This error does not
occur.
This error does not
occur.
This error does not
occur.
The connection was
stopped because the
Tag Data Link Stop
Bit was turned ON,
or the settings data
is being downloaded.
Either turn ON the
Tag Data Link Start
Switch, or wait until
the settings data has
been downloaded.
This code includes
fatal Controller errors
and Unit failure. To
handle these errors,
refer to 15-1-1 How
to Check for Errors.
Wait until the open-
ing processing is
completed.
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
Handling
Configuration 2
Configuration 3
Depends on the tar-
Depends on the origi-
get's specifications.
nator's specifications.
(Contact the target
(Contact the originator
device's manufacturer.)
device's manufacturer.)
Check the target's con-
Check the connection
nection settings (num-
settings (number of
ber of connections and
connections and RPI)
RPI). Check the con-
at the originator and
nection settings (num-
target.
ber of connections and
RPI) at the originator
and target.
Depends on the tar-
Depends on the origi-
get's specifications.
nator's specifications.
(Contact the target
(Contact the originator
device's manufacturer.)
device's manufacturer.)
Depends on the tar-
Depends on the origi-
get's specifications.
nator's specifications.
(Contact the target
(Contact the originator
device's manufacturer.)
device's manufacturer.)
Depends on the tar-
Depends on the origi-
get's specifications.
nator's specifications.
(Contact the target
(Contact the originator
device's manufacturer.)
device's manufacturer.)
Depends on the tar-
Depends on the origi-
get's specifications.
nator's specifications.
(Contact the target
(Contact the originator
device's manufacturer.)
device's manufacturer.)
The originator gener-
Depends on the origi-
ates this code when an
nator's specifications.
unsupported response
(Contact the originator
code is returned from
device's manufacturer.)
the target in reply to an
open request.
Depends on the tar-
Depends on the origi-
get's specifications.
nator's specifications.
(Contact the target
(Contact the originator
device's manufacturer.)
device's manufacturer.)
The meaning of this
Depends on the origi-
error code is defined by
nator's specifications.
each vendor, so it
(Contact the originator
depends on the target's
device's manufacturer.)
specifications. (Con-
tact the target device's
manufacturer.)
The meaning of this
Depends on the origi-
error code is defined by
nator's specifications.
each vendor, so it
(Contact the originator
depends on the target's
device's manufacturer.)
specifications. (Con-
tact the target device's
manufacturer.)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac nx-seriesSysmac nx1p2-10 seriesSysmac nx1p2-90 seriesSysmac nj501-5 seriesSysmac nj501-4 seriesSysmac nj501-3 series ... Show all

Table of Contents