Variable name
_EIP_TDLinkOpnErr
Meaning
Tag Data Link Connection Failed
Function
NX-series CPU Units: Indicates that establishing a tag data link connection for CIP communications 1 failed.
TRUE: Establishing a tag data link connection failed due to one of the following causes.
FALSE: Other than the above.
NJ-series CPU Units: Indicates that establishing a tag data link connection failed.
TRUE: Establishing a tag data link connection failed due to one of the following causes.
FALSE: Other than the above.
Data type
BOOL
R/W access
R
Usage in user pro-
Possible.
gram
Variable name
_EIP1_TDLinkOpnErr
Meaning
CIP Communications1 Tag Data Link Connec-
tion Failed
Function
Indicates that establishing a tag data link connection for CIP communications 1 failed.
TRUE: Establishing a tag data link connection failed due to one of the following causes.
FALSE: Other than the above.
Note You can use this system-defined variable only for NX-series CPU Units.
Data type
BOOL
R/W access
R
Usage in user pro-
Possible.
gram
Variable name
_EIP2_TDLinkOpnErr
Meaning
CIP Communications2 Tag Data Link Connec-
tion Failed
Function
Indicates that establishing a tag data link connection for CIP communications 2 failed.
TRUE: Establishing a tag data link connection failed due to one of the following causes.
FALSE: Other than the above.
Note You can use this system-defined variable only for the NX701 CPU Units.
Data type
BOOL
R/W access
R
Usage in user pro-
Possible.
gram
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
3 System-defined Variables Related to the Built-in EtherNet/IP Port
•The information registered for a target node in the tag data link parameters is different from the actual
node information.
•There was no response from the remote node.
•The information registered for a target node in the tag data link parameters is different from the actual
node information.
•There was no response from the remote node.
Retained
Not retained.
Related
---
instructions
•The information registered for a target node in the tag data link parameters is different from the actual
node information.
•There was no response from the remote node.
Retained
Not retained.
Related
---
instructions
•The information registered for a target node in the tag data link parameters is different from the actual
node information.
•There was no response from the remote node.
Retained
Not retained.
Related
---
instructions
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
3