3 System-defined Variables Related to the Built-in EtherNet/IP Port
Variable name
_EIP_TargetPLCModeSta [255]
Meaning
Target PLC Operating Mode
Function
NX-series CPU Units: Shows the operating status of the target node Controllers that are connected for CIP com-
munications 1, with the built-in EtherNet/IP port as the originator.
The array elements are valid only when the corresponding Normal Target Node Information is TRUE. If the corre-
sponding Normal Target Node Information is FALSE, the Target Node Controller Operating Information indicates
the previous operating status.
Array[x] is TRUE: This is the operating state of the target Controller with a node address of x.
Array[x] is FALSE: Other than the above.
NJ-series CPU Units: Shows the operating status of the target node Controllers that are connected with the built-in
EtherNet/IP port as the originator.
The array elements are valid only when the corresponding Normal Target Node Information is TRUE. If the corre-
sponding Normal Target Node Information is FALSE, the Target Node Controller Operating Information indicates
the previous operating status.
Array[x] is TRUE: This is the operating state of the target Controller with a node address of x.
Array[x] is FALSE: Other than the above.
Data type
ARRAY [0..255] OF BOOL
R/W access
R
Usage in user pro-
Possible.
gram
Variable name
_EIP1_TargetPLCModeSta [255]
Meaning
CIP Communications1 Target PLC Operating
Mode
Function
Shows the operating status of the target node Controllers that are connected for CIP communications 1, with the
built-in EtherNet/IP port as the originator.
The array elements are valid only when the corresponding Normal Target Node Information is TRUE. If the corre-
sponding Normal Target Node Information is FALSE, the Target Node Controller Operating Information indicates
the previous operating status.
Array[x] is TRUE: This is the operating state of the target Controller with a node address of x.
Array[x] is FALSE: Other than the above.
Note You can use this system-defined variable only for NX-series CPU Units.
Data type
ARRAY [0..255] OF BOOL
R/W access
R
Usage in user pro-
Possible.
gram
Variable name
_EIP2_TargetPLCModeSta [255]
Meaning
CIP Communications2 Target PLC Operating
Mode
Function
Shows the operating status of the target node Controllers that are connected for CIP communications 2, with the
built-in EtherNet/IP port as the originator.
The array elements are valid only when the corresponding Normal Target Node Information is TRUE. If the corre-
sponding Normal Target Node Information is FALSE, the Target Node Controller Operating Information indicates
the previous operating status.
Array[x] is TRUE: This is the operating state of the target Controller with a node address of x.
Array[x] is FALSE: Other than the above.
Note You can use this system-defined variable only for the NX701 CPU Units.
Data type
ARRAY [0..255] OF BOOL
R/W access
R
Usage in user pro-
Possible.
gram
3-54
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
---
instructions
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.