Omron Sysmac NJ-series User Manual page 308

Machine automation controller cpu unit built-in ethernet/iptm port
Hide thumbs Also See for Sysmac NJ-series:
Table of Contents

Advertisement

8 CIP Message Communications
Response Codes
CIP
status
00
SUCCESS
02
RESOURCE_UNAVAILABLE
04
PATH_SEGMENT_ERROR
05
PATH_DESTINATION_UNKNOWN
0C
OBJECT_STATE_CONFLICT
13
NOT_ENOUGH_DATA
15
TOO_MUCH_DATA
1F
VENDOR_SPECIFIC_ERROR
20
INVALID_PARAMETER
8-62
Meaning
0102, 2103
0104, 1103
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
Add
Cause
status
---
The service ended normally.
---
The internal processing buffer is not
available.
---
The request path specification is not cor-
rect.
---
The link was followed to the end, but the
variable was not found.
8010
Downloading, starting up
8011
There is an error in tag memory.
---
The data length was too short for the
specified service.
---
The data length was too long for the
specified service.
An attempt was made to write a constant
or read-only variable.
The specified address and size exceed
a segment boundary.
8001
An internal error occurred. (An informa-
tion inconsistency was detected in the
interface in the Module.)
8007
An inaccessible variable was specified.
8029
A region that all cannot be accessed at
the same time was specified for Simple-
DataSegment.
8031
An internal error occurred. (A memory
allocation error occurred.)
8009
A segment type error occurred.
800F
There is an inconsistency in data length
information in the Request Data.
8017
More than one element was specified for
a variable that does not have elements.
8018
Zero elements or data that exceeded the
range of the array was specified for an
array.
8021
A value other than 0 or 2 was specified
for an AddInfo area.
8022
The data type that is specified in the
request service data does not agree with
the tag information. The AddInfo Length
in the request service data is not 0.
8023
An internal error occurred. (An illegal
command format was used.)
8024
An internal error occurred. (An illegal
command length was used.)
8025
An internal error occurred. (An illegal
parameter was used.)
8027
An internal error occurred. (A parameter
error occurred.)
8028
• An attempt was made to write an out-
of-range value for a variable for which
a subrange is specified.
• An attempt was made to write an
undefined value to an enumeration
variable.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac nx-seriesSysmac nx1p2-10 seriesSysmac nx1p2-90 seriesSysmac nj501-5 seriesSysmac nj501-4 seriesSysmac nj501-3 series ... Show all

Table of Contents