17. Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used in
this appliance.
18. The appliance area must be kept clear and
free of combustible materials, (gases and other
flammable vapours and liquids).
19. Do not use this appliance if any part has been
under water. Immediately call a qualified ser-
vice technician to inspect the appliance and to
replace any part of the electrical control system
and any gas control which has been under water.
WARNING: Failure to position the
20.
parts in accordance with the diagrams
in this manual or failure to use only
parts specifically approved with this
appliance may result in property
damage or personal injury.
WARNING: Operation of this appliance
21.
when not connected to a properly
installed and maintained venting
system or tampering with the blocked
vent shut-off system can result in
carbon monoxide (CO) poisoning and
possible death.
8
|
Regency
®
E18E Gas Fireplace Insert
INSTALLATION
CHECKLIST
1. Locate your appliance. Refer to the "Clearances
to Combustibles" and "Minimum Fireplace
Clearances" sections.
2. Make gas and electrical connections. Refer to
the "Gas Connection" section.
Test the pilot. Refer to the "Pilot Adjustment"
section.
3. Install Flue Connector. Refer to the section on
installation specifications.
4. Install vent. Refer to the "Venting" section.
5. Test Gas pressure. Refer to the "Gas Pipe
Pressure Testing" section.
Check aeration. Refer to the "Gas Insert Aera-
tion System" section.
6. Test for flue spillage. Refer to the "Drafthood
Check" section.
7. Install standard and optional features. Refer
to the following sections where applicable:
a. Brick or Enamel Panels
b. Faceplate & Trim
c. Circulation Fan
d. Remote Control
e. Wall Switch
f. Wall Thermostat
8. Final check. Refer to the "Final Check" section.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to customer.
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label) after burning
appliance for 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
3. Ensure that the appliance is venting correctly.
CAUTION: Any alteration to the product that
causes sooting or carboning that results in dam-
age is not the responsibility of the manufacturer.
Specifications
For Altitude: Natural Gas
Propane:
Burner Orifice Sizes:
Natural Gas Propane
Burner
#44
Max. Input Rating
- Natural Gas
21,600 Btu/h
- Propane
20,500 Btu/h
Min. Input Rating
- Natural Gas +/-5% 15,000 Btu/h
-Propane
+/-5%
17,000 Btu/h
Supply Pressure
Natural Gas
min. 5.0" w.c.
Propane
min. 12.0" w.c.
Manifold Pressure (High)
Natural Gas
3.5"
Propane
10"
Circulation Fan: 120 VAC, 60 Hz
Variable Speed: 127 CFM, thermally
actived

GAS CONNECTION

Only persons licensed to work with gas piping
may make the necessary gas connections to this
appliance.
The gas connection is a 1/2" NPT accessible on the
left side of the unit. The gas line connection may
be made of rigid pipe, copper pipe or an approved
flex connector. (If you are using rigid pipe, ensure
that the valve can be removed for servicing.) Since
some municipalities have additional local codes it
is always best to consult with your local authorities
and the CAN/CGA B149 installation code.
For USA installations follow local codes and/or the
current National Fuel Gas Code, ANSI Z223.1.
When using copper or flex connectors use only
approved fittings. Always provide a union so that
gas lines can be easily disconnected for burner or
fan servicing. Flare nuts for copper lines and flex
connectors are usually considered to meet this
requirement.
Important: Always check for gas leaks
with a soap and water solution or gas
leak detector. Do not use open flame for
leak testing.
0-4500 ft.
0-4500 ft.
#55
+/- 0.2" w.c.
+/- 0.2" w.c.