installer's information

Minimum Fireplace Opening

The minimum fireplace openings for the Regency GFi750 gas space heater are shown below:
Height
Lintel Depth (mm)
(mm)
200
590
8
|
Regency GFi750 Gas Inbuilt Fireplace
Width Front
Depth
(mm)
(mm)
685
200
565
685
Width-Back
(mm)
400
565
Side View
Top View

Installation Checklist

Before installing vent system ensure that the damper
plate is open and secure to prevent the damper plate
from falling down and crushing the liner.
The FPI Gas Inbuilt is installed as listed.
1. Check all clearances to combustibles, (Refer
to sections "Minimum Fireplace Opening and
Clearances to Combustibles)
2. Make the gas connection. (Refer to section "Gas
Connection")
3. Install the 76 mm and 102 mm flue liner to the
sliding connector plate. (Refer to section "Flue
Liner Installation.")
4. Slide the unit half way into the fireplace.
5. Pull the vent connector plate through the tapered
brackets and fasten to the front plate. Refer to
section "Flue Liner Installation.")
6. Slide the unit fully into the fireplace.
7. Test gas pressure (Refer to section "Gas Pipe
Pressure Testing"). Check aeration system (Refer
to section "Gas Insert Aeration System").
8. Install standard and optional features. Refer
to the following sections:
a. Log Set
b. Door, Primary Guard & Faceplate
c. Inner Glass Panels (optional)
9. Final check: Before leaving this unit with the
customer, the installer must ensure that the
appliance is firing correctly. This includes:
a) Clocking the appliance to ensure the correct
firing rate.
b) Adjusting the primary air and restrictor set-
tings, if required, to ensure that the flame
does not carbon.