installation
|
18
MODIFICATION OF MONTIGO EP28-2, EP28-4
OR EP28-5
*Units could have any of the following Log Sets Installed: 2LB (2 Log Set),
MB (2 Log Set), 4LB (4 Log Set)
1. Turn off unit, disconnect Gas and Power.
2. Remove Upper and Lower Louvers.
3. Remove Optional Doors or Screen Mesh.
4. Remove Logs.
5. Remove Bottom Door Rail (See Diagram 5.1).
6. Remove Burner Assembly (See Diagram 5.1).
7. Cut the front bar out on the left and right sides of the firebox. (See
Diagram 5.2). Grind the corners smooth on the left side - to reduce the
risk of wires being cut. Alternate method is to cut front bar in the center
and break off each side spot weld completely.
Grind corners
18 |
Regency
®
E18E Gas Fireplace Insert
Diagram 5.1
Diagram 5.2
8. Remove hood and inner baffle (See Diagram 5.3).
9. Bend down the three flanges at the bottom of the firebox or cut them off
(See Diagram 5.4).
Modified edges must be flush to allow proper seating of the E18E
Diagram 5.3
Diagram 5.4
outer shell.