8. Remove Efficiency Collar (See Diagram 6.6).
9. Remove Fan (See Diagram 6.7).
10. Remove the leftover ends of the front bar on the Left and Right sides so
that they are flush with the sides of the firebox. (See Diagram 6.8)
Diagram 6.6
Diagram 6.7
Diagram 6.8
11. Bend Down the Three Flanges at the Bottom of the Firebox or Cut them
Off (see Diagram 6.9).
Edges must be flush to allow proper seating of the
E18E outerbox.
E18E INSTALL SPECIFICATIONS
See Installation of E18E into Existing Units for General Installation
Guidance.
Vent Connection Type A
This install of the E18E uses
The Length of 4" Flex needed is approximately 4-1/8" semi-expanded.
From this point installation is the same as the EP28-5.
Regency
installation
Diagram 6.9
.
E18E Gas Fireplace Insert
®
|