Regency Energy E18E Owners & Installation Manual page 41

Gas insert
Hide thumbs Also See for Energy E18E:
Table of Contents

Advertisement

E18E Install Specifications
See Installation of E18E into Existing Units for General Installation Guidance.
This install of the E18E uses Vent Connection Type A.
The Length of 4" Flex needed is 1-15/16" semi-expanded. Secure flue adapter top plate to under side of existing firebox using 4 self tap-
ing screws.
Secure top plate to firebox w/4 screws.
Secure vent slide plate to flex pipe with 4
screws
Firesong 220N Installation Specifications
Firesong 220N Firebox
5 - 3/16"
[132mm]
2 1/8"
54mm
Leg Setting / Outer Shell Position
1. Loosen 2 x Phillips screws on both right and left legs.
2. See above diagram below for required leg setting.
3. Install with supplied Phillips screws to prepunched holes and tighten previous
screws that were loosened in Step 1.
E18 Insert
4. Keep left side leg loose until outer firebox is in position in ZC box - to allow
adjustment of gas line.
2 1/8"
54mm
Leg Setting / Outer Shell Position
E18 Insert
Collar Plate Setting / Vent position
E18 Insert
5 1/4"
133mm
C
Firesong 220N Firebox
Vents on center
D
5 1/4"
133mm
C
Firesong 220N Firebox
Vents on center
D
Firesong 220N faceplate is an outside fit, if the front metal face
of the 220N is covered with stone or tile - a custom faceplate
8 3/16"
will be required.
208mm
The following measurements of the 220N metal face will be
visible if no stone or tile is covering it. If this metal face is vis-
ible, the standard Faceplate (616-920) will fit.
Set to this
hole
Leg height setting
1"
(25mm)
Right side shown
Flex Adaptor Length
8 3/16"
208mm
installation
Leg height setting
Flex Adaptor Length
DETAIL D
SCALE 1 : 4
Firesong 220N
Front Facing measurements
DETAIL C
SCALE 1 : 4
1 15/16"
49mm
Regency
E18E Gas Fireplace Insert
®
|
41
DETAIL C
SCALE 1 : 4
1 15/16"
49mm
Set to this
hole
Adaptor Plate
Fastener Setting
3"
(76mm)
Note: this measurement
is above lower area
3"
(76mm)
|
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

E18e-lpE18e-ng

Table of Contents