Installation Checklist; Materials Required; Minimum Fireplace Dimensions - Regency L540E-NG1 Owners & Installation Manual

Table of Contents

Advertisement

InsTALLATIOn
CHECkLIST
Before installing vent system ensure that the damper
plate is open and secure to prevent the damper plate
from falling down and crushing the liner.
The Regency Gas Insert is installed as listed.
1) Check all clearances to combustibles, (Refer to
sections "Minimum Fireplace Dimensions and
Clearances to Combustibles)
2) Make the gas connection. (Refer to section "Gas
Connection") Gas connection is on the left side
of the appliance.
3) Install the two flue liners (intake and exhaust)
to the sliding connector plate. (Refer to section
"Flue Liner Installation.")
4) Slide the unit half way into the fireplace.
5) Pull the vent connector plate through the
brackets and fasten to the front plate. Refer to
section "Flue Liner Installation.")
6) Slide the unit fully into the fireplace. Level if
necessary.
7) Install 4-AA batteries into receiver.
8) Plug the 3 wire cord into a suitable receptacle.
The 3 wire cord is located on the right side of
the unit.
9) Code remote control. See Remote Control
Instruction Manual.
10) Test gas pressure (Refer to section "Gas Pipe
Pressure Testing"). Check aeration system
(Refer to section "Gas Insert Aeration System").
11) Install standard and optional features. Refer to
the following sections:
a. Brick Panels
b. Enamel Panels
c. Log Set
d. Glass Crystals
e. Spa stones
f
1
. Low Profile Faceplate with Optional Screen
f
. Full Screen Door
2
L540E / HZI540E Direct Vent Gas Insert
12) final check: Before leaving this unit with the
customer, the installer must ensure that the
appliance is firing correctly. This includes:
a) Clocking the appliance to ensure the correct
firing rate.
b) Adjusting the primary air, if required, to
ensure that the flame does not carbon. See
"Gas Insert Aeration System" section.
c) Ensuring that the appliance is venting
correctly.

MATErIALs rEquIrEd

Electrical power supply (120V) is required for the
gas control and fan to operate as this unit is supplied
with a GTMF remote control system which operates
both the gas valve and fan. Plug the 3 wire cord
into a suitable receptacle. do not cut the ground
terminal off under any circumstances. When
connected with 120 volts, the appliance must be
electrically grounded in accordance with local
codes, current version of CSA C22.1 (in Canada)
or in the absence of local codes, with the National
Electrical Code ANSI/NFPA 70-1987.
installation
MInIMuM FIrEpLAcE
dImENSIONS
The minimum fireplace clearances & dimensions
for the Regency gas insert are shown in the
following diagrams:
A
B
C
D
E
Max Lentil
Bar Depth
Height
Depth
A
B
C
Low
10"
24"
16.75"
Profile
Faceplate
Full
10"
24"
16.75"
Screen
Doors
Width
Width
(rear)
(front)
D
E
25"
34"
25"
34"
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hzi540eL540eL540e-lp1Hzi540e-ng1Hzi540e-lp1

Table of Contents