installation
|
50
ZERO CLEARANCE FACEPLATE INSTALLATION
ZERO CLEARANCE FACEPLATE INSTALLATION
1. Shut down existing unit and allow to cool to room temperature.
2. Turn off gas supply and disconnect electrical.
3. Remove all accessories from existing unit, ie. glass doors, louvers,
etc.
4. Remove any tiles, hearth or surround from existing unit (if required).
5. Disconnect gas supply from existing unit.
6. Cut away a perimeter of drywall around the existing unit to expose
the framing. See example below.
7. Uninstall existing unit from framing.
8. Disconnect venting from existing unit - remove carefully to avoid damage.
9. Remove existing unit from framed opening.
10. Measure framed opening and compare to dimension requirements.
Additional adjustments to framed opening may be required.
50 |
Regency
®
E18E Gas Fireplace Insert
919-831a
Cut drywall
Remove unit from framing
ZERO CLEARANCE FRAMING DIMENSIONS
Framing
Description
Dimensions
A
Framing Height
B
Framing Width
C
Framing Depth
Electrical connection: 110v required
Fan must be on at all times to operate this unit.
1
E18E
E18E
36" (914mm)
37 - 7/16" (951mm)
15-1/2" (394mm)
11.29.17