Command
DIG CONTROL
DIG CONTROL = command
1
8
DISPENSEA
DISPENSEB
DISPENSEC
DISPENSED
DISPENSEA=#
DISPENSEB=#
DISPENSEC=#
DISPENSED=#
FLOW
FLOWCD
FLOWA
FLOWB
FLOWC
FLOWD
FLOW=#
FLOWB=#
FLOWC=#
FLOWD=#
G
GG
G&
G&2
IDENTIFY
Table 8-6 Serial Commands (Continued)
Description
Returns the status of the digital output control bits as either REMOTE (R) or INTER-
NAL (I). The return message format is DIG CONTROL=xxxxxx, where "x" is either
"R" or "I". "R" indicates the corresponding bit is controlled remotely; and "I" indicates
the corresponding bit is controlled internally by pump software. The status order
returned corresponds with the outputs 1—8.
Sets the digital output control bits to either internal or remote, where "x" is either "R"
for REMOTE or "I" for INTERNAL CONTROL. "R" indicates the corresponding bit will
be controlled remotely (through the serial port). "I" indicates the corresponding bit
will be controlled internally by pump software. The order corresponds with the out-
puts 1—8.
Returns the dispense volume for Dispense mode.
Sets the dispense volume for Dispense mode. Format is XXX.XXX ml. Leading and
trailing zeros are not required. Can only be changed when pump is stopped.
Returns the delivering pump's flow rate in continuous pumping mode and modifier
addition mode. In INDEPENDENT mode FLOW returns the pump A flow rate and
FLOWCD returns the pump C flow rate.
Returns the actual flow rate of the pump.
Returns the actual flow rate of the pump Enter # for a flow rate setpoint (constant
flow mode). Format is XXX.XXXXXXX ml/min. Only 5 figures are significant. Leading
and trailing zeros are not required.
Gets pump information. "G" returns a text string that contains current pressure, ana-
log input, and digital input information. "G&" is the Get All command. This returns the
same information as "G," plus flow rates, units, operation status, and more. For four
pump operation ise the G&2 commands. Refer to 8.8.1 for a complete description of
this serial command.
Pump responds "SERIES=1240-0___, MODEL ____D PUMP; REV__." For each
pump, REV__ is the internal pump program software revision. (For example, if the
controller was attached to two 100DMs, the message would read
"SERIES=1240-024, MODEL 100DM PUMP; SERIES=1240-024, MODEL 100DM;
REV__.") The series number is the original catalog number for the pump type. It may
not match the production series number on the pump serial label.
SERIES=1240-024, MODEL 100DM PUMP
SERIES=1240-027, MODEL 100DX PUMP
SERIES=1240-021, MODEL 260D PUMP
SERIES=1240-025, MODEL 500D PUMP
SERIES=1240-103, MODEL 500HPx PUMP
SERIES=1240-052, MODEL 1000D PUMP
SERIES=1240-063, MODEL 65D PUMP
SERIES=1240-096, MODEL 65DM PUMP
SERIES=1240-819, MODEL 30D PUMP
D Series Syringe Pumps
Section 8 Serial Interface
8-21