Teledyne D series Installation And Operation Manual page 151

Table of Contents

Advertisement

Read/
Register Address
Write
40071
70
R/W
40073
72
R
40075
74
R
40077
76
R
40079
78
R
40081
80
R
40083
82
R
40085
84
R
40087
86
R
40089
88
R
40091
90
R
40093
92
R
40095
94
R
40097
96
R
40099
98
R
40101
100
R
40103
102
R
40105
104
R
40107
106
R
40109
108
R
40111
110
R
40113
112
R
40115
114
R
40117
116
R/W
40119
118
R/W
40121
120
R/W
40123
122
R/W
40125
124
R/W
40127
126
R/W
Table 7-6 Holding Registers (Continued)
# of
Type
Description
Registers
Maximum flow limit in Constant Pressure
FLOAT
2
mode for Pump D.
FLOAT
2
Actual pressure of Pump A.
FLOAT
2
Actual flow rate of Pump A.
FLOAT
2
Volume remaining in Pump A.
FLOAT
2
Actual pressure of Pump B.
FLOAT
2
Actual flow rate of Pump B.
FLOAT
2
Volume remaining in Pump B.
FLOAT
2
Actual pressure of Pump C.
FLOAT
2
Actual flow rate of Pump C.
FLOAT
2
Volume remaining in Pump C.
FLOAT
2
Actual pressure of Pump D.
FLOAT
2
Actual flow rate of Pump D.
FLOAT
2
Volume remaining in Pump D.
FLOAT
2
System flow rate of multi-pump pair AB.
FLOAT
2
System pressure of multi-pump pair AB.
Total volume delivered by multi-pump pair
FLOAT
2
AB.
FLOAT
2
System flow rate of multi-pump pair CD.
FLOAT
2
System pressure of multi-pump pair CD.
Total volume delivered by multi-pump pair
FLOAT
2
CD.
Analog voltage input on Analog Input 1 of
FLOAT
2
the accessory connector.
Analog voltage input on Analog Input 2 of
FLOAT
2
the accessory connector.
Analog voltage input on Analog Input 3 of
FLOAT
2
the accessory connector.
Analog voltage input on Analog Input 4 of
FLOAT
2
the accessory connector.
Volume at which Pump A will automatically
FLOAT
2
switch to refill mode if AUTO REFILL A is ON.
Volume at which Pump B will automatically
FLOAT
2
switch to refill mode if AUTO REFILL B is ON.
Volume at which Pump C will automatically
FLOAT
2
switch to refill mode if AUTO REFILL C is ON .
Volume at which Pump D will automatically
FLOAT
2
switch to refill mode if AUTO REFILL D is ON.
Volume that Pump A will be refill to if AUTO
FLOAT
2
FILL TO A is ON.
Volume that Pump B will be refill to if AUTO
FLOAT
2
FILL TO B is ON.
D Series Syringe Pumps
Section 7 Modbus Configuration
Units
ml/min; ml/hr; ul/min; ul/hr See NOTE 2.
ATM; BAR; kPa; PSI See NOTE 1.
ml/min; ml/hr; ul/min; ul/hr See NOTE 2.
milliliters
ATM; BAR; kPa; PSI See NOTE 1.
ml/min; ml/hr; ul/min; ul/hr See NOTE 2.
milliliters
ATM; BAR; kPa; PSI See NOTE 1.
ml/min; ml/hr; ul/min; ul/hr See NOTE 2.
milliliters
ATM; BAR; kPa; PSI See NOTE 1.
ml/min; ml/hr; ul/min; ul/hr See NOTE 2.
milliliters
ml/min; ml/hr; ul/min; ul/hr See NOTE 2.
ATM; BAR; kPa; PSI See NOTE 1.
Liters
ml/min; ml/hr; ul/min; ul/hr See NOTE 2.
ATM; BAR; kPa; PSI See NOTE 1.
Liters
Volts
Volts
Volts
Volts
milliliters
milliliters
milliliters
milliliters
milliliters
milliliters
7-9