Teledyne D series Installation And Operation Manual page 148

Table of Contents

Advertisement

D Series Syringe Pumps
Section 7 Modbus Configuration
Table 7-5 Coils (Continued)
Register
Address
00078
77
00079
78
00080
79
00081
80
00082
81
00083
82
00084
83
00085
84
00086
85
00087
86
00088
87
00089
88
00090
89
00091
90
00092
91
00093
92
00094
93
00095
94
00096
95
00097
96
00098
97
00099
98
00100
99
00101
100
00102
101
00103
102
00104
103
00105
103
00106
105
00107
106
00108
107
00109
108
00110
109
00111
110
00112
111
00113
112
00114
113
7-6
Type
Size
Description
R/W
1 BIT
0: DIGITAL OUTPUT BIT 8 HIGH 1: DIGITAL OUTPUT BIT 8 LOW
0: Disable Dispense Mode A 1: Enable Dispense Mode A Only configure if in Constant Flow
R/W
1 BIT
Mode
0: Disable Dispense Mode B 1: Enable Dispense Mode B Only configure if in Constant Flow
R/W
1 BIT
Mode
0: Disable Dispense Mode C 1: Enable Dispense Mode C Only configure if in Constant Flow
R/W
1 BIT
Mode
0: Disable Dispense Mode D 1: Enable Dispense Mode D Only configure if in Constant Flow
R/W
1 BIT
Mode
R/W
1 BIT
1: Reset total volume delivered by multi-pump pair AB
R/W
1 BIT
1: Reset total volume delivered by multi-pump pair CD
R/W
1 BIT
1: Pressure Units =ATM
R/W
1 BIT
1: Pressure Units = BAR
R/W
1 BIT
1: Pressure Units = kPa
R/W
1 BIT
1: Pressure Units = PSI
R/W
1 BIT
1: Flow Units = ml/min
R/W
1 BIT
1: Flow Units = ml/hr
R/W
1 BIT
1: Flow Units = ul/min
R/W
1 BIT
1: Flow Units = ul/hr
R/W
1 BIT
0: Overpressure Alarm OFF 1: Overpressure Alarm ON
R/W
1 BIT
0: Overpressure Display OFF 1: Overpressure Display ON
R/W
1 BIT
0: Overpressure Shutdown OFF 1: Overpressure Shutdown ON
R/W
1 BIT
0: Underpressure Alarm OFF 1: Underpressure Alarm ON
R/W
1 BIT
0: Underpressure Display OFF 1: Underpressure Display ON
R/W
1 BIT
0: Underpressure Shutdown OFF 1: Underpressure Shutdown ON
R/W
1 BIT
0: Overflow Alarm OFF 1: Overflow Alarm ON
R/W
1 BIT
0: Overflow Display OFF 1: Overflow Display ON
R/W
1 BIT
0: Overflow Shutdown OFF 1: Overflow Display ON
R/W
1 BIT
0: Underflow Alarm OFF 1: Underflow Alarm ON
R/W
1 BIT
0: Underflow Display OFF 1: Underflow Display ON
R/W
1 BIT
0: Underflow Shutdown OFF 1: Underflow Shutdown ON
R/W
1 BIT
0: Poor Fill Alarm A OFF 1: Poor Fill Alarm A ON
R/W
1 BIT
0: Poor Fill Alarm B OFF 1: Poor Fill Alarm B ON
R/W
1 BIT
0: Poor Fill Alarm C OFF 1: Poor Fill Alarm C ON
R/W
1 BIT
0: Poor Fill Alarm D OFF 1: Poor Fill Alarm D ON
R/W
1 BIT
1: Stop all motor and reset flow rate and pressure set-points to default.
R
1 BIT
0: Transducer of Pump A not connected 1: Transducer of Pump A connected
R
1 BIT
0: Pump A not at upper flag limit 1: Pump A at upper Flag Limit (Empty)
R
1 BIT
0: Pump A not at lower flag limit 1: Pump A at lower flag limit (Full)
R
1 BIT
1: Pump A is overpressure
R
1 BIT
1: Pump A is underpressure

Hide quick links: