Daikin RXYQ96PYDN Service Manual page 346

R-410a heat pump 60hz, r-410a heat recovery 60hz
Hide thumbs Also See for RXYQ96PYDN:
Table of Contents

Advertisement

SiUS34-801A_b
Malfunction
code
Outdoor Unit
L1
L4
L5
L8
L9
LA
LC
P1
P4
PJ
System
U0
U1
U2
U3
U4
U5
U5
U7
U8
U9
UA
UC
UE
UF
UH
Central
M1
Remote
Controller
M8
and
Schedule
Timer
MA
MC
Heat
64
Reclaim
65
Ventilation
6A
6A
6F
6H
94
The system operates for malfunction codes indicated in black squares, however, be sure to check and repair.
Troubleshooting
Operation
Inspection
Unit No.
lamp
display
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
8
7
9
9
9
9
9
9
9
9
9
9
7
8
9
9
9
9
9
9
9
9
8
8
9
9
9
9
9
9
8 or 7
9
8 or 7
9
8 or 7
9
8 or 7
9
8
7
8
7
8
7
9
9
8
7
8
7
9
9
Malfunction contents
Malfunction of inverter PC board
9
Malfunction of inverter radiating fin temperature rise
9
DC output overcurrent of inverter compressor
9
Inverter current abnormal
9
Inverter start up error
9
Malfunction of power unit
9
Malfunction of transmission between inverter and
9
control PC board
Inverter over-ripple protection
9
Malfunction of inverter radiating fin temperature rise
9
sensor
Faulty field setting after replacing main PC board or
9
faulty combination of PC board
Gas shortage alert
9
Reverse phase / open phase
9
Power supply insufficient or instantaneous failure
9
Check operation is not completed.
9
Malfunction of transmission between indoor and
9
outdoor units
Malfunction of transmission between remote controller
9
and indoor unit
Failure of remote controller PC board or setting during
7
control by remote controller
Malfunction of transmission between outdoor units
9
Malfunction of transmission between main and sub
7
remote controllers (malfunction of sub remote controller)
Malfunction of transmission between indoor unit and
9
outdoor unit in the same system
Improper combination of indoor and outdoor units,
9
indoor units and remote controller
Address duplication of central remote controller
8
Malfunction of transmission between central remote
9
controller and indoor unit
Refrigerant system not set, incompatible wiring / piping
9
Malfunction of system, refrigerant system address
9
undefined
Central remote controller PC board defect
9
Schedule timer PC board defect
Malfunction of transmission between optional
9
controllers for centralized control
Improper combination of optional controllers for
9
centralized control
Address duplication, improper setting
9
Indoor unit's air thermistor error
9
Outside air thermistor error
9
Damper system alarm
9
Damper system + thermistor error
9
Malfunction of simple remote controller
9
Malfunction of door switch or connector
9
Internal transmission error
9
Troubleshooting by Remote Controller
8: ON
7: OFF
9: Blink
Page
391
393
396
398
400
403
406
408
410
412
414
415
418
419
424
424
421
431
432
433
439
440
443
444
446
447
453
451
331